A filming technique using Side Scan SONAR should be varied upon condition in order to obtain high-resolution data. Because the theoretical measurement scope is different from the actual measurement scope. It is possible to obtain the accurate data only after adjusting the water depth, distance from a structure and emission angle. Via the multiple regression analysis of data accumulated through field experiments and relations of 3 variables, and equation was devised.