Recently efficient maintenance technology has been rising because of the structural deterioration. Specific technology development and research related to the real-time monitoring has been conducted in various ways. All-in-one enclosure including GPS was fabricated to measure the displacement of the retaining wall structure exposed the extreme environment such as very high and low temperature. Also it measured the displacement of the structure under the phased construction.