논문 상세보기

Reliability Study of Measuring Range of Motion Glenohumeral Joint Internal Rotation With Pressure Biofeedback Stabilization KCI 등재

  • 언어ENG
  • URLhttps://db.koreascholar.com/Article/Detail/309766
구독 기관 인증 시 무료 이용이 가능합니다. 4,000원
한국전문물리치료학회지 (Physical Therapy Korea)
한국전문물리치료학회 (Korean Research Society of Physical Therapy)
초록

The aims of the current study were to assess reliability of range of motion (ROM) measurement of glenohumeral internal rotation (GIR) with a pressure biofeedback stabilization (PBS) method and to compare the reliability between manual stabilization (MS) and the PBS method. In measurement of pure glenohumeral joint motion, scapular stabilization is necessary. The MS method in GIR ROM measurement was used to restrict scapular motion by pressing the palm of the tester’s hand over the subject’s clavicle, coracoid process, and humeral head. The PBS method was devised to maintain consistent pressure for scapular stabilization during GIR ROM measurement by using a pressure biofeedback unit. GIR ROM was measured by 2 different stabilization methods in 32 subjects with GIR deficit using a smartphone clinometer application. Repeated measurements were performed in two test sessions by two testers to confirm inter- and intra-rater reliability. After tester A performed measurements in test session 1, tester B’s measurements were conducted one hour later on the same day to assess the inter-rater reliability and then tester A performed again measurements in test session 2 for confirming the intra-rater reliability. Intra-class correlation coefficient (ICC) (2,1) was applied to assess the inter-rater reliability and ICC (3,1) was applied to determine the intra-rater reliability of the two methods. In the PBS method, the intra-rater reliability was excellent (ICC=.91) and the inter-rater reliability was good (ICC=.84). The inter-rater and intra-rater reliability of the PBS method was higher than in the MS method. The PBS method could regulate manual scapular stabilization pressure in inter- and intra-rater measuring GIR ROM. Results of the current study recommend that the PBS method can provide reliable measurement data on GIR ROM.

목차
Introduction
Methods
Discussion
Conclusion
References
저자
  • Ui-jae Hwang(Kinetic Ergocise Based on Movement Analysis Laboratory, Dept. of Physical Therapy, The Graduate School, Yonsei University)
  • Sung-min Ha(Dept. of physical Therapy, College of Health Science, Sangji University)
  • In-chul Jeon(Kinetic Ergocise Based on Movement Analysis Laboratory, Dept. of Physical Therapy, The Graduate School, Yonsei University)
  • Sung-hoon Jung(Kinetic Ergocise Based on Movement Analysis Laboratory, Dept. of Physical Therapy, The Graduate School, Yonsei University)
  • Kyu-hwan Choi(Dept. of Physical Therapy, Ansan University)
  • Su-jung Kim(Dept. of Physical Therapy, College of Health Sciences, Youngsan University)
  • Oh-yun Kwon(Kinetic Ergocise Based on Movement Analysis Laboratory, Dept. of Physical Therapy, College of Health Science, Yonsei University, Dept. of Ergonomic Therapy, The Graduate School of Health and Environment, Yonsei University) Corresponding author