원전 냉각수 취수용 지중매설 GFRP관의 구조적 거동 조사 KCI 등재

An Investigation of Structural Behavior of Underground Buried GFRP Pipe in Cooling Water Intake for the Nuclear Power Plant

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/312531
구독 기관 인증 시 무료 이용이 가능합니다. 4,000원
복합신소재구조학회 논문집 (Journal of the Korean Society for Advanced Composite Structures)
한국복합신소재구조학회 (Korean Society for Advanced Composite Structures)
초록

GRP pipe (Glass-fiber Reinforced Plastic Pipe) lines making use of FRP (Fiber Reinforced Plastic) are generally thinner, lighter, and stronger than the existing concrete or steel pipe lines, and it is excellent in stiffness/strength per unit weight. In this study, we present the result of field test for buried GRP pipes with large diameter(2,400mm). The vertical and horizontal ring deflections are measured for 387 days. The short-term deflection measured by the field test is compared with the result predicted by the Iowa formula. In addition, the long-term ring deflection is predicted by using the procedure suggested in ASTM D 5365(ANNEX) in the range of 40 to 60 years of service life of the pipe based on the experimental results. From the study, it was found that the long-term vertical and horizontal ring deflection up to 60 years is less than the 5% ring deflection limitation.

목차
1. INTRODUCTION
2. Mechanical Properties of GRP Pipe
3. Design of Ring Deflection
4. Full-Scale Field Test
5. Long-term Ring Deflection of GRP Pipe
6. CONCLUSION
ACKNOWLEDGEMENT
References
저자
  • 이형규(서일대학교 토목과 교수) | Lee, Hyoung-Kyu Corresponding author
  • 박준석(홍익대학교 과학기술연구소) | Park, Joon-Seok