논문 상세보기

일부 PC방내 니코틴 농도와 호흡성분진(RSP) 입경별 상관성 KCI 등재후보

The Correlation between the Airborne Nicotine Concentration and the Size Distribution of Respirable Suspended Particulates (RSP) in the PC Game Room

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/31590
구독 기관 인증 시 무료 이용이 가능합니다. 4,600원
한국실내환경학회지 (Journal of Korean Society for Indoor Environment)
한국실내환경학회 (Korean Society for Indoor Environment)
초록

The PC game rooms in Korea have a problem in the aspect of indoor air quality because there are many occupants for 24 hours where the smoking is allowed. This study was carried out to evaluate indoor air quality (IAQ) including the size distribution of respirable suspended particulates (RSP) and airborne nicotine concentration in selected PC game rooms. The subjects are 6 PC game rooms in Seoul and Sung-Nam Cities. In this study, airborne RSP and nicotine concentrations were measured during a period from February to March, 2003. Significant correlation has been found between the concentrations of RSP and nicotine in PC game room. Also the negative correlation was found between room area and number of operating fan. The correlation coefficients between RSP size distribution and nicotine concentration were 0.868, 0.866, 0.870 in the stages 2 (cut-point 14.80㎛), 5 (cut-point 3.50㎛), and 8 (cut-point 0.52㎛) from Marple's 8-stage cascade impactor, respectively. In conclusion, RSP concentration in PC game room has a tendency to increase by smoking. Therefore, it is suggested that the effective air control system and education program be applied for PC game room.

저자
  • 노영만
  • 김윤신
  • 손종열
  • 정재열