논문 상세보기

HPLC 분석기법에 기초한 아세톤과 아크롤레인의 피크분리 기초 연구 KCI 등재후보

A Study on the Peak Separation of Acetone and Acrolein based on HPLC method

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/31663
구독 기관 인증 시 무료 이용이 가능합니다. 4,300원
한국실내환경학회지 (Journal of Korean Society for Indoor Environment)
한국실내환경학회 (Korean Society for Indoor Environment)
초록

To resolve coelution phenomenon of acetone and acrolein in the HPLC‐based analysis of carbonyls, we attempted to find the optimal conditions for their separation. For the purpose of this study, the collection of carbonyl Compounds is made by DNPH‐coated cartridges. Quantification of carbonyls is then initiated by the formation of hydrazone derivatives that are then separated by HPLC and detected by UV‐VIS spectroscopic detector (at 360 nm). To the course of this experiment, we examined the influences of the three major experimental variables such as 5 temperature (25, 30, 40, 50 and 60℃), 2 flow rate (1.0 and 1.2 mL min‐1), and variable relative composition of mobile phase (among acetonitrile, water, and tetrahydrofuran). According to our experiments, the optimal condition for separation was found at flow rate of 1.2 mL min‐1 and temperature of 32℃ with the mobile phase composition of acetonitrile:water:tetrahydrofuran = 34 : 52.8 : 13.2.

저자
  • 고은주
  • 김신도
  • 김기현