논문 상세보기

서고환경의 실내공기질에 관한 연구 KCI 등재후보

Indoor Air Quality(IAQ) in Stock Rooms

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/31706
구독 기관 인증 시 무료 이용이 가능합니다. 4,000원
한국실내환경학회지 (Journal of Korean Society for Indoor Environment)
한국실내환경학회 (Korean Society for Indoor Environment)
초록

The purpose of this study are to examin the level of temperature, relative humidity and pollutants at stock rooms in National Archives and to provide fundamental data in order to protect damage of archives. The survey of indoor air quality(IAQ) in stock rooms was performed in Busan National Archives in August and December 2007, and collected basic data, on level of them at stock rooms in National Archives that were published. The temperature and relative humidity in stock rooms were within the terms of national law of the public archives administration. The concentration of PM10 in stock rooms in National Archives exceeded 50 ㎍/m3, which is the guideline of national law for the public archives administration. The concentration of CO, SO2, NO2, O3 and Formaldehyde in stock rooms did not exceeded the guideline of national law. The concentration of total volatile organic compounds was shown to exceed the guideline of natioanl law. Therefore, we suggest that a national plan for the management of IAQ at stock rooms in National Archives should be established through a long-term, continuous investigation

저자
  • 이철민
  • 김우재
  • 이정주
  • 봉춘근
  • 조장우
  • 김윤신