논문 상세보기

전단 보강재의 보강길이에 따른 기초판의 뚫림전단 성능평가 KCI 등재

Punching Shear Performance Evaluation of Foundation by Enforcement-length of Shear Head Reinforcement

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/322703
서비스가 종료되어 열람이 제한될 수 있습니다.
한국구조물진단유지관리공학회 논문집 (Journal of The Korea Institute for Structural Maintenance and Inspection)
한국구조물진단유지관리공학회 (The Korea Institute For Structural Maintenance and Inspection)
초록

This study was made to examine the motion characteristics according to the reinforcement of the reinforcement length and stiffener reinforcement for shear reinforcement to the foundation structure reinforced with shear reinforcement steel plate. Experimental study was made after specimen was installed on the ground as the same as in the practical site. Reinforcement lengths of the steel for shear reinforcement are divided into 1,000 mm, 1,200 mm and 1,400 mm in the specimen and as for reinforcement method of the stiffener, 4 stiffeners with interval of 100mm reinforced with the same materials as the shear reinforcement were manufactured for the experiment. Considering result of the experiment, it is expressed that no effect of the stiffener reinforcement was found and regarding the reinforcement length of shear reinforcement material the crossed point of the two converted lines of the value that the shear force is expressed in the bearing power in the expanded dangerous section and the value that the shear capacity receivable by the reinforcement materials in the dangerous section is proposed as effective reinforcement length.

저자
  • 이용재(동양미래대학교 건축과 교수) | Yong-Jae Lee
  • 이원호(광운대학교 건축공학과 교수) | Waon-Ho Yi
  • 양원직(광운대학교 환경대학원 교수) | Won-Jik Yang Corresponding author