논문 상세보기

나선형 원형철근으로 보강된 집중배치 텐던 정착구역에 대한 하중전달시험 KCI 등재

Load Transfer Test of Spirally Reinforced Anchorage Zone for Banded Tendon Group

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/324237
구독 기관 인증 시 무료 이용이 가능합니다. 4,000원
한국공간구조학회지 (JOURNAL OF THE KOREAN ASSOCIATION FOR AND SPATIAL STRUCTURES)
한국공간구조학회 (Korean Association for Spatial Structures)
초록

In this study, load transfer tests based on KCI-PS101 were conducted to verify the performance of spiral anchorage zone reinforcement for banded post-tensioning (PT) monostrands. With results, the compressive strength of spiral reinforcement was increased by about 20% than that of specimens with two horizontal steel bars and 8% than that of U-shaped bars. Advanced spiral reinforcement for corner increases compressive strength and can resist the spalling forces or fall-out effect at the corner by shear. The ratio of maximum load to amount of steel of the spiral reinforcement is about twice than that of U-shaped reinforcement. With increase of compressive strength capacity and improvement of constructability, the spiral reinforcement is considered to have advantages of promoting the performance of PT anchorage zone compared to conventional methods.

저자
  • 조아서(서울대학교 건축학과 박사과정) | Cho, Ah
  • 강현구(서울대학교 건축학과 교수, 공학박사) | Kang, Thomas H.-K. 교신저자