In this study, the mixing method of positive paste and mixing temperature to improve the capacity of the lead-acid batteries has been investigated. The results show that the initial current capacity of lead acid battery depend on the mixing temperature and mixing method of positive paste. In the results of the capacity cycle repetition tests for estimating the life cycle, the 3BS showed the PCL. but the fine 4BS represented certain improved cycles compared to that of the coarse 4BS. It was considered that the fine 4BS showed higher bond strength between active materials than the coarse 4BS and represented large contact areas and that lead to prevent possible sulfation due to the suppression of insulating layers.