논문 상세보기

TID and SEL Testing on OP-Amp. of DC/DC Power Converter KCI 등재

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/331064
서비스가 종료되어 열람이 제한될 수 있습니다.
Journal of the Korean Society of Radiology (한국방사선학회논문지)
한국방사선학회 (The Korea Society of Radiology)
초록

DC/DC switching power converters are commonly used to generate a regulated DC output voltage with high efficiency. The advanced DC/DC converter uses a PWM-IC with OP-Amp. (Operational Amplifier) to control a MOSFET (metal-oxide semiconductor field effect transistor), which is a switching component, efficiently. In this paper, it is shown that the electrical characteristics of OP-Amp. are affected by radiations of γ rays using 60Co for TID (Total Ionizing Dose) testing and 5 heavy ions for SEL (Single Event Latch-up) testing. TID testing on OP-Amp. is accomplished up to the total dose of 30 krad, and the cross section(㎠) versus LET(MeV/mg/㎠ ) in the OP-Amp. operation is evaluated SEL testing after implementation of the controller board.

저자
  • Young Hwan Lho(Department of Railroad Electricity System, Woosong University) Corresponding Author