논문 상세보기

Multi echo T2 Corrected Single Voxel Spectroscopy를 이용한 Hepatic Fat Quantification의 유용성에 관한 고찰 KCI 등재

A Study on the Usefulness of Hepatic Fat Quantification Using Multi echo T2 Corrected Single Voxel Spectroscopy

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/340545
구독 기관 인증 시 무료 이용이 가능합니다. 4,000원
Journal of the Korean Society of MR Technology (대한자기공명기술학회지)
대한자기공명기술학회 (The Korean Society of MR Technology)
초록

목 적 : 본 연구는 Multi echo T2 Corrected Single Voxel Spectroscopy(SVS-HISTO) 기법으로 얻은 간의 지방률을 현재 임상에서 사용되고 있는 Dixon 기법과 비교하여 SVS-HISTO 기법을 이용한 지방간 정량화의 유용성을 알아보고자 하였다.
대상 및 방법 : 2014년 1월~2월 간이식 제공을 목적으로 Liver Donor MRI 검사를 시행한 22명(남성 13명, 여성 9명)의 환자를 대상으로 하였다. 3.0T 자기공명영상장치(NUMARIS/4 syngo MR D13, Magnetom Verio, Siemens)와 32channel body array coil을 이용하였고, Multi echo T2 Corrected Single Voxel Spectroscopy(SVSHISTO) 기법과 Three-Point Dixon(3PD), Six-Point Dixon(6PD) 기법을 사용하여 간의 지방률을 측정하였다. 통계학적인 검정은 SPSS 22.0(SPSS Inc, Chicago, IL, USA)를 이용해 p<0.05 일 때 유의한 것으로 해석하였다.
결 과 : 비모수 검정인 Wilcoxon sign rank test를 이용한 평균 비교는 SVS-HISTO와 3PD의 평균차이 -0.03(p=0.984), 6PD와의 평균차이 0.24(p=0.249)로 통계적으로 유의한 차이가 없음을 알 수 있었고, 3PD와 6PD의 평균차이는 0.27(p=0.007)이었으며 p<0.05로 유의한 차이를 보였다. Spearman 상관분석에서 SVS-HISTO와 3PD의 상관계수는 r=0.945로 p<0.001로 나타났고, 6PD은 r=0.951로 p<0.001이었다.
결 론 : Multi echo T2 Corrected Single Voxel Spectroscopy(SVS-HISTO) 기법은 한 번의 호흡정지로 Multi-Echo를 획득할 수 있으며 복잡한 후처리 과정 없이 T2*가 보정된 Fat percentage를 얻을 수 있었다. 통계분석을 통해 SVS-HISTO 기법과 3PD, 6PD 기법 간 Hepatic Fat Fraction값은 유의한 차이가 없음을 확인할 수 있었다. 따라서 SVS-HISTO 기법은 호흡정지가 필요한 복부 검사에 적용함에 있어서 유용할 것으로 사료된다.

Purpose : This study is compared the fat rate to evaluate the usefulness of hepatic fat quantification measured by Multi echo T2 Corrected Single Voxel Spectroscopy(SVS-HISTO) with Dixon method currently used in clinics.
Materials and Methods : Between January to February 2014 Liver Donor MRI scan with the objective of providing transplantation was performed in 22 patients(male 13, female 9). 3.0T MR system(NUMARIS/4 syngo MR D13, Magnetom Verio, Siemens) was used with 32channel body array coil. The fat ratio was measured by Multi echo T2 Corrected Single Voxel Spectroscopy(SVS-HISTO) method and Three-Point Dixon (3PD), Six-Point Dixon(6PD) technique. The SPSS 22.0(SPSS Inc, Chicago,IL, USA) program was used for statistical analysis and the significance level was set below p
Results : Using the non-parametric Wilcoxon sign rank test, the SVS-HISTO average compared with 3PD mean difference was -0.03(p=0.984), and 6PD mean difference was 0.24(p=0.249). This is shown the no significant difference. The correlation coefficient between the SVS-HISTO and 3PD was r=0.945 and 6PD was r=0.951.
Conclusion : Multi echo T2 Corrected Single Voxel Spectroscopy(SVS-HISTO) with a single breath-hold technique is able to obtain a Multi-Echo and to get the fat fraction calculating T2* without complex post-processing. Thus SVS-HISTO on abdominal examination needed the breath-hold techniques is considered useful.

목차
Ⅰ. 서 론
 Ⅱ. 대상 및 방법
  1. 대 상
  2. 검사 장비
  3. 자기공명분광법
  4. Dixon
  5. 분석 방법
 Ⅲ. 결 과
 Ⅳ. 결론 및 고찰
 Ⅴ. 참고문헌
저자
  • 신연진(서울대학교병원 영상의학과) | Yeon-jin Shin
  • 정우진(서울대학교병원 영상의학과) | Woo-Jin Jeong
  • 서재범(서울대학교병원 영상의학과) | Jae-beom Seo
  • 방용식(서울대학교병원 영상의학과) | Yong-sik Bang
  • 김동성(서울대학교병원 영상의학과) | Dong-seong Kim