Even if the amount of exhaust gas is the same, it is possible to reduce the exhaust gas exit heat at the outlet of the boiler facility by lowering the outlet temperature of the economizer, so that it is possible to increase the heat quantity recovered from the boiler facility. There are many cases where the existing facility adopts 220~250℃ as the design value of the exhaust gas temperature at the exit of the economizer. However, in recent years, there has been a case of cooling and recovering heat to 200℃ or less from the viewpoint of active heat recovery. The amount of combustion exhaust gas is reduced by reducing the amount of combustion air supplied to the incinerator, and the amount of heat exhausted from the boiler facility is reduced, thereby improving the boiler efficiency. The holding energy of the combustion exhaust gas is the product of the exhaust gas amount and the specific heat and the temperature. In order to recover more heat from the combustion exhaust gas, not only the heat loss in the boiler facility is reduced, but also the heat radiated from the boiler facility is reduced. It is effective to reduce the exhaust gas temperature at the outlet of the heat recovery equipment and reduce the amount of exhaust gas in order to reduce the amount of exhaust heat of the exhaust gas. Even if the exhaust gas temperature at the outlet of the economizer is the same, the amount of exhaust gas discharged at the boiler facility outlet is reduced by reducing the amount of exhaust gas, and an increase in the recovered heat quantity at the boiler is expected.