논문 상세보기

Nd : YAG 펄스 레이저 스캐닝 시스템을 이용한 볼트 풀림 감지

Bolt Looseness Detection Using an Nd: YAG Pulsed Laser Scanning System

  • 언어ENG
  • URLhttps://db.koreascholar.com/Article/Detail/346393
서비스가 종료되어 열람이 제한될 수 있습니다.
한국구조물진단유지관리공학회 (The Korea Institute For Structural Maintenance and Inspection)
초록

The aim of this study is to assess a looseness in a bolt being utilized for connecting components of a structural elements with the help of an Nd:YAG pulsed laser scanning system. Ultrasonic wave propagation imaging (UWPI) of a waveform generated using laser light and recorded by AE sensor was first found. Filtering operation was performed to remove an incident wave. The energy in the reflected wave was further assessed to arrive at a result which indicates structural defect has appeared, i.e., bolt loosening.

목차
Abstract
 1. Introduction
 2. Research Method
 3. Experimental Study
 4. Conclusion
 References
저자
  • 카사훈 데미시 톨라(성균관대학교 건설환경시스템공학과) | Kassahun D. Tola
  • 유병준(성균관대학교 미래도시융합공학과) | Yoo, Byung Jun
  • 박지환(성균관대학교 미래도시융합공학과) | Park, Jihwan
  • 박승희(성균관대학교 건설환경공학부) | Park, Seunghee 교신저자