In this study, an experimental study of Impulse Thermography was carried out on a concrete specimen with in-placed artificial defects at different depths and dimensions. Then, all the data were processed by Pulse Phase Thermography technique by performing Fast Fourier Transformation. The results were compared with the absolute contrast method.