논문 상세보기

산화마그네슘 세라믹 합성 보수재료의 염화물 확산계수 시험 기술 고찰

Discussion on Chloride Penetration Test Using Concrete Repaired with Magnesium Polymer Ceramic Material

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/346591
서비스가 종료되어 열람이 제한될 수 있습니다.
한국구조물진단유지관리공학회 (The Korea Institute For Structural Maintenance and Inspection)
초록

In this study, chloride penetration in a repaired concrete using magnesium polymer ceramic (MPC) was assessed based on the NT BUILD 492. To investigate the effect of repaired material on chloride penetration, a cylinder OPC concrete specimen was fabricated and attached on the surface with MPC. Then, chloride penetration test was carried out on the combined concrete sample at a constant applied voltage (30 V) for 6 hours. It was found that most of chloride sources was passed though the interface between OPC and MPC, resulting in a loss of chloride in the material. Thus, it is needed to modify the conventional chloride penetration test for the repaired concrete specimen.

목차
Abstract
 1. 서 론
 2. 해석계획 및 방법
 3. 해석결과 및 고찰
 4. 결 론
 참고문헌
저자
  • 장낙섭(경남과학기술대학교 토목공학과) | Jang, Nag Seop
  • 김흥봉(경남과학기술대학교 토목공학과) | Kim, Heung Bong 교신저자
  • 김영환(경남과학기술대학교 토목공학과) | Kim, Young Hwan 교신저자
  • 오홍섭(경남과학기술대학교 토목공학과) | Oh, Hong Seob 교신저자