논문 상세보기

포항지진에 대한 원자력발전소 구조물 및 기기의 지진응답 분석 KCI 등재

Seismic Response Analysis of Nuclear Power Plant Structures and Equipment due to the Pohang Earthquake

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/347320
구독 기관 인증 시 무료 이용이 가능합니다. 4,000원
한국지진공학회 (Earthquake Engineering Society of Korea)
초록

The probabilistic seismic safety assessment is one of the methodology to evaluate the seismic safety of the nuclear power plants. The site characteristics of the nuclear power plant should be reflected when evaluating the seismic safety of the nuclear power plant. The Korea seismic characteristics are strong in high frequency region and may be different from NRC Regulatory Guide 1.60, which is the design spectrum of nuclear power plants. In this study, seismic response of a nuclear power plant structure by Pohang earthquake (2017.11.15. (KST)) is investigated. The Pohang earthquake measured at the Cheongsong seismic observation station (CHS) is scaled to the peak ground acceleration (PGA) of 0.2 g and the seismic acceleration time history curve corresponding to the design spectrum is created. A nuclear power plant of the containment building and the auxiliary buildings are modeled using OPENSEES to analyze the seismic response of the Pohang earthquake. The seismic behavior of the nuclear power plant due to the Pohang earthquake is investigated. And the seismic performances of the equipment of a nuclear power plant are evaluated by the HCLPF. As a result, the seismic safety evaluation of nuclear power plants should be evaluated based on site-specific characteristics of nuclear power plants.

목차
A B S T R A C T
 1. 서 론
 2. 지진응답해석을 위한 입력지진
  2.1 포항지진의 특징
  2.2 원자력발전소 설계응답스펙트럼에 부합하는 인공지진 생성
 3. 원자력발전소의 층응답스펙트럼
  3.1 격납건물의 층응답스펙트럼
  3.2 보조건물의 층응답스펙트럼
 4. 원자력발전소 전기기기의 내진성능
  4.1 CPC/CEAC 캐비닛의 내진성능 비교
  4.2 MCC 캐비닛의 내진성능 비교
 5. 결 론
 REFERENCES
저자
  • 임승현(한국원자력연구원 구조지진안전연구실) | Eem, Seung-Hyun Corresponding author
  • 최인길(한국원자력연구원 구조지진안전연구실) | Choi, In-Kil