Background : Eleutheroside E (Syringaresinol-di-O-glucoside), one of the internal standard in Eleutherococcus senticosus (Rupr. & Maxim.) Maxim., showed effects on the anti-inflammation of arthritis and the decline in blood sugar. In this study, it was analyzed by using high performance liquid chromatography (HPLC) to find out the optimum experimental condition which indicated the highest content of eleutheroside E.
Methods and Results: In total of 15 different experimental conditions were used to extract samples. Briefly, there were three different conditions in the temperature (room temperature, 70℃ and 100℃) and five solvent conditions (100% water, 30% EtOH, 50% EtOH, 70% EtOH and 100% EtOH) were used. The extraction condition of all samples were extracted in every 4 hours and repeated three times with a reflux cooling system. The HPLC was reported as eleutheroside E standard equivalents using the following linear equation based on the calibration curve : equation : Y = 7.72e + 0.04X – 7.83e + 004, R2 = 0.999918. Among 15 conditions, eleutheroside E was obtained with the highest amount (10.36 ± 3.81 ㎎/g of extract) at 100% EtOH extracted and room temperature condition. In this study, the eleutheroside E content was increased with increasing of EtOH concentration. And it can be detected by heating at 100% water extraction condition.
Conclusion : These results demonstrated that the experimental condition at room temperature in 100% EtOH could be used in further studies to obtain the highest content of eleutheroside E in Eleutherococcus senticosus (Rupr. & Maxim.) Maxim.