전기비저항 측정에서 전극 위치에 따른 영향

Effect of Electrodes Location on Electrical Resistivity Measurement

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/356594
서비스가 종료되어 열람이 제한될 수 있습니다.
한국구조물진단유지관리공학회 (The Korea Institute For Structural Maintenance and Inspection)
초록

In this study, the relation between the direction of the reinforcing bars and the arrangement of the electrodes in the concrete resistivity measurement was experimentally examined. The results showed that the apparent resistivity was lower in the parallel measurement with the reinforced concrete bars, and the value of the apparent resistivity was higher as the measurement direction is closer to perpendicularity against the rebar.

목차
Abstract
 1. 서 론
 2. 측정방향에 따른 겉보기 비저항의 영향
 3. 실험결과 및 결론
 참고문헌