This study was carried out to evaluate the pollutant removal efficiencies of the advanced drinking water treatment using ozonation process. For raw water, Nakdong River was used. By conducting batch test of ozonation, the following results were obtained. When ozone dosage of 5 mg/ℓ was used, ozone transfer and utilization efficiencies of the ozonation were 94 to 92%, respectively. Removal efficiencies of single VOC compound or mixed VOC compounds in the raw water were 80% to 90% by the ozonation with 2 mg/ℓ dosage and 10 minutes contact time. Removal efficiencies of ABS by the ozonation with 1 mg/ℓ, 3 mg/ℓ dosage and 20 minutes contact time were 83% to 96% , respectively. Almost 67% of chlorophyll-a at the concentration of 38.4㎍/ℓ was removed by ozonation at ozone dosage of 1 ㎎/ℓ for 20 min.
Considering the efficiency of ozone utilization and water treatment, the most effective ozonation could be obtained with high ozone dosage and short contact time.