Calculation of the Convective Mixed Layer by Estimation of Sensible Heat Flux
A Jump model was evaluated for the calculation of hourly mixing height and mean potential temperature within the height. The Jump model was modified for estimation of downward heat fluxes by mechanical convections and surface heat fluxes. The surface heat fluxes were estimated from routine weather data such as solar radiation and air temperature. Total of 8 upper-air data observed at 0000UTC and 0600UTC in Osan station during April 23 to 26, 1996 were analyzed, and compared to the model results in detail. The calculated mixing heights and potential temperatures within the height were comparable to the observations, but some differences were showed. The calculated mixing heights were generally higher than observations. And, when variations of wind directions were large, the large difference of potential temperature was occurred. From the results, it was important to note that vertical motions and advections of air masses would affect to the growth of the mixing height.