Organophosphate pesticides were extracted with 70% acetone and then transferred to dichloromethane. Extracts were applied to open-column chromatography with florisil The final extract was analyzed by gas chromatography with nitrogen-phosphorus detector(GC/NPD). Recoveries of the 18 organophosphate pesticides were ranged from 88.7% to 100.0% for the narrow-bore capillary GC(Ultra-2). The minimum detectable level of this analytical method was 0.019 - 0.035 ㎎/㎏. Sample throughput(extraction, open-column chromatography, and GC analysis) was decreased considerably (8h per sample).