This research provides techniques for the implementation of an integrity evaluation system developed for wind turbine structures to jack-up barge. The strain values obtained from the upper tip of the footing are to be converted into values at a single point in order to represent the structural behavior. These obtained values are evaluated simultaneously through P-M curve, generated by FEM results. Evaluating loads with P-M curve, structural stability of barge could then be monitored.