논문 상세보기

CHLOROFORM BODY BURDEN FROM BATHING KCI 등재

목욕으로 인한 클로로포름의 인체부담

  • 언어ENG
  • URLhttps://db.koreascholar.com/Article/Detail/369644
서비스가 종료되어 열람이 제한될 수 있습니다.
한국환경과학회지 (Journal of Environmental Science International)
한국환경과학회 (The Korean Environmental Sciences Society)
초록

There has been an increased awareness of the need to confirm the chloroform exposure associated with using chlorinated household water. Ten of a 30-minute tub bath were normally taken by two volunteers in a bathroom of an apartment. Chloroform concentrations were measured in bathing water and bathroom air, and exhaled breath of the subjects prior to and after bathing. Bathing using chlorinated tap water resulted in a chloroform exposure and caused a body burden. Based on the difference of chloroform concentrations between breath samples collected prior to and after bathing, the chloroform body burden from a 30-minute bath was estimated to be about 8 to 26 folds higher than that prior to the bath. The mean water and bathroom air chloroform concentrations measured to evaluate the body burden were 9.4 ㎍/ℓ and 14.9 ㎍/㎥, respectively. The chloroform level of the bathroom air was 34 to 130 times higher than that of the living-room air. The relationship between the bathroom air and the corresponding breath chloroform concentrations were significant with p=0.03 and R^2=0.47.

저자
  • Wan Kuen Jo | 조완근
  • Young Mee Hwang | 황영미