논문 상세보기

압착식 조인트가 적용된 파이프라인의 비선형 유한요소 해석

Nonlinear Finite Element Analysis of Stainless Power Joints Piping System

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/371227
모든 회원에게 무료로 제공됩니다.
한국복합신소재구조학회 (Korean Society for Advanced Composite Structures)
초록

Recently, the incidence and magnitude of earthquakes have been continuously increasing. NFPA 13 requires that hydroponics fire extinguishing system pipelines apply seismic isolation. Stainless steel joints have been newly developed to replace these seismic isolation joints. Therefore, in this study, a nonlinear finite element model of a pipeline with Stainless Power Joint was developed based on experimental data, and finite element analysis was performed by applying hydrostatic pressure and cyclic loading.

목차
ABSTRACT
 1. 서 론
 2. 압착식 조인트가 적용된 파이프라인의 내진성능 평가 실험
 3. 파이프라인의 유한요소 모델
 4. 유한요소 해석 결과
 5. 결론
 References
저자
  • 손호영(경희대학교 사회기반시스템공학과) | Son Ho-Young
  • 주부석(경희대학교 사회기반시스템공학과) | Ju Bu-Seog
  • 소우빈(경희대학교 사회기반시스템공학과) | So Woo-Bin
  • 박성관(경희대학교 사회기반시스템공학과) | Park Seong-Gwan