Structural insulated panels, structurally performed panels consisting of a plastic insulation bonded between two structural panel facings, are one of emerging products with a viewpoint of its energy and construction efficiencies. Of the SIPs, Cyclic test was conducted by two kinds of specimens: single panel and double panels. Cyclic test results, which were equivalent to static test results, showed that maximum load was 45.42kN, allowable shear load was 6.3kN/m. Furthermore the accumulated energy dissipation capability for double panels was as 2.3 times as that for single panel. From performance of structural tests, the allowable shear load for panels was suggested to be at least 6.1kN/m.

목차
ABSTRACT
 1. 서 론
 2. 시험 및 결과분석
  2.1 시험방법
  2.2 시험체 구성
 3. 반복가력 시험결과 분석
  3.1 시험체(SIPC-D) 분석 결과
  3.2 시험체(SIPC-D) 에너지소산능력
 4. 결론
 References