Incheon is an area where complaints about odors occur frequently and there are many sources of odor emission. In this study, we used a real-time monitoring device to measure the odorous concentration near the areas where there are complaints about odors. The measurements were carried out for the three areas (G, C, S) that are located around emissions sources. G is situated in an industrial complex that has a reputation for being one of the most foul smelling regions of Incheon. A petroleum refining plant and storage facility are located around C. S is a residential area nearby an industrial site. The concentration of major designated odor substances in the G and S areas satisfied the site boundary emission standards. With regard to the characteristics of odor substances by region, although the C area region had the highest odor intensity among the three regions due to the odor intensity near the oil storage facility areas G and S were similar in terms of odor intensity. In the region of the G area, the odor intensity was slightly higher at the northern side of t he industrial complex. In terms of the odor intensity of the designated odor substances, trimethyl amine was the strongest, followed by hydrogen sulfide. The real time monitoring system was necessary to analyze the changing trends of odor substances and for the determination of major odor sources. This study was conducted to identify the material causes of odors in areas of Incheon where there are frequent complaints about major odors.