논문 상세보기

EMP 기술표준 동향 및 군용 RF 안테나 유입 EMP 신호 분석 KCI 등재

Recent EMP Standards and Analysis of EMP Signal Coming into Military RF Antenna

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/427121
구독 기관 인증 시 무료 이용이 가능합니다. 4,000원
한국기계기술학회지 (Journal of the Korean Society of Mechanical Technology)
한국기계기술학회 (Korean Society of Mechanical Technology)
초록

In this paper, the EMP-related standards and test methods used by the civilian and military have been introduced. The incoming EMP signal for seven military RF antennas which are the first to face EMP threats among military weapon systems have been also measured and analyzed. Overall, as the applied signal strength increased, the strength of the EMP signal entering in the antenna also showed an upward trend. The highest level of entering was observed at the peak value of the applied EMP signal, 50 kV/m. And at the peak value, all antennas received threatening signals. In particular, antennas in low frequency bands such as AM and FM were getting high voltage signals as high as thousands of volts. This means that the weapon systems linked to the antennas could suffer severe damage. Therefore, based on this paper, systematic research for EMP threat should be conducted to identify EMP vulnerabilities of major weapons systems and to devise practical protective measures.

저자
  • 정성빈(국방기술품질원) | Sung-Bin Jung (Defence Agency of Technology and Quality) Corresponding author
  • 윤재복(국방기술품질원) | Jae-Bok Yoon (Defence Agency of Technology and Quality)
  • 이기림(국방기술품질원) | Gi-Rim Lee (Defence Agency of Technology and Quality)