논문 상세보기

Performance Test of A 100 kW Class Mobile Plasma Melting System for Non-combustible Wastes

  • 언어ENG
  • URLhttps://db.koreascholar.com/Article/Detail/429998
모든 회원에게 무료로 제공됩니다.
한국방사성폐기물학회 학술논문요약집 (Abstracts of Proceedings of the Korean Radioactive Wasts Society)
한국방사성폐기물학회 (Korean Radioactive Waste Society)
초록

In this work, we report the basic performance of a 100 kW class mobile plasma melting system consisting of two 24-ft commercial containers, each in charge of the plasma utilities and melting process. In this system, a 100 kW class transferred type plasma torch has been installed together with a crucible having an inner volume of 2,884 cm3. Filling the inner volume of the crucible with the simulated metal waste, such as bolts and nuts, melting tests have been carried out for 5 min by varying plasma input power from 50 kW to 100 kW. By measuring the volume of metal waste before and after melting test, then, the volume reduction rates were estimated and discussed.

저자
  • Darian Figuera-Michal(JeonBuk National University (JBNU))
  • Dong-Hyun Lee(JeonBuk National University (JBNU))
  • Nam-Ki Lee(JeonBuk National University (JBNU))
  • Sang-Min Jeong(ORION EnC)
  • Jun-Ho Seo(JeonBuk National University (JBNU)) Corresponding author