초록

Organic scintillator is easy to manufacture a large size and the fluorescence decay time is short. However, it is not suitable for gamma measurement because it is composed of a low atomic number material. Organic scintillation detectors are widely used to check the presence or absence of radiation. The fluorescence of organic scintillators is produced by transitions between the energy levels of single molecules. In this study, an organic scintillator development study was conducted for use in gamma measurement, alternative materials for secondary solute used in basic organic scintillators were investigated, and the availability of alternative materials, detection characteristics, and neutron/gamma identification tests were performed. In other words, a secondary solute showing an improved energy transfer rate than the existing material was reported, and the performance was evaluated. 7-Diethylamino -4-methylcoumarin (DMC), selected as an alternative material, is a benzopyrone derivative in the form of colorless crystals, has high fluorescence and high quantum yield in the visible region, and has excellent light stability. In addition, it has a large Stokes shift characteristic, and solubility in solvent is good. Through this study, it was analyzed that the absorption wavelength range of DMC coincided with the emission wavelength range of PPO, which is the primary solute. Through this study, it was confirmed that the optimal concentration of DMC was 0.04wt%. As a result of performing gamma and neutron measurement tests using a DMC-based liquid scintillator, it showed good performance (FOM=1.42) compared to a commercial liquid scintillator. Therefore, the possibility of use as a secondary solute was demonstrated. Based on this, if studies on changes in the composition of secondary solute or the use of nanoparticles are conducted, it will be possible to manufacture and utilize a scintillator with improved efficiency compared to the existing scintillator.

저자
  • Su Jung Min(Kyung Hee University, Korea Atomic Energy Research Institute (KAERI))
  • Yong Dae Park(Korea Atomic Energy Research Institute (KAERI))
  • Bum Kyung Seo(Korea Atomic Energy Research Institute (KAERI))
  • Chang Hyun Roh(Korea Atomic Energy Research Institute (KAERI))
  • Sang Bum Hong(Korea Atomic Energy Research Institute (KAERI)) Corresponding author
  • Jae Hak Cheong(Kyung Hee University)