논문 상세보기

터널형 방음시설의 화재 리스크 및 구조적 위험요인 분석 KCI 등재후보

Analysis of Fire Risk Structural Risk Factors in Tunnel-Type Soundproofing Facilities

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/444983
구독 기관 인증 시 무료 이용이 가능합니다. 4,000원
대한안전경영과학회지 (Journal of Korea Safety Management & Science)
대한안전경영과학회 (Korea Safety Management & Science)
초록

This study experimentally and numerically evaluated the fire risks and structural vulnerabilities of tunnel-type noise barriers (hereinafter referred to as hereinafter referred to as soundproof tunnels). In Korea, soundproof tunnels are typically constructed using combustible polymeric materials such as polymethyl methacrylate (PMMA) and polycarbonate (PC) for noise reduction and lightweight design. However, due to their enclosed structural characteristics, concerns have been raised regarding heat and smoke accumulation as well as the rapid spread of fire. In this study, fire scenarios were established by varying structural conditions, including roof opening ratios and the presence or absence of central partitions, and analyzed using the Fire Dynamics Simulator (FDS). The results demonstrated that PMMA exhibited a lower thermal decomposition temperature and a higher heat release rate, indicating a higher level of fire risk, while PC showed superior fire resistance with higher decomposition temperature and delayed ignition properties. PMMA rapidly exceeded the critical thresholds for temperature and radiative heat flux, resulting in complete combustion. Central partitions were found to accelerate smoke spread, whereas side or roof openings facilitated smoke discharge to the exterior, contributing to fire suppression and improving life safety. In conclusion, this study confirmed that the fire risks of soundproof tunnel are jointly influenced by the combustion characteristics of the materials and the structural conditions. The findings are expected to serve as fundamental data for material selection and design standard improvements in future soundproof tunnel fire safety.

목차
Abstract
1. 서 론
2. 선행연구 분석
3. 국내외 방음터널 현황 및 자재 특성
    3.1 국내 방음터널의 설치 및 자재 현황
    3.2 해외 방음터널 설치 및 화재안전 적용 사례
4. 화재 시뮬레이션을 통한 위험성 평가
    4.1 시뮬레이션 개요 및 목적
    4.2 모델링 설정 및 조건
    4.3 주요 결과 분석
5. 결론 및 제언
6. References
저자 소개
저자
  • 하용우(대전대학교 대학원 방재학과 박사과정) | Yong-Woo Ha (Department of Disaster Prevention, Graduate School, Daejeon University)
  • 황철홍(대전대학교 소방방재학과 교수) | Cheol-Hong Hwang (Department of Fire and Disaster Prevention, Daejeon University) Corresponding author