Underground Roadway Entrance Lighting Design Based on Pupil-Size Changes
Underground roadway entrances require drivers to adapt to substantial differences in brightness between outdoor and interior environments. Therefore, lighting design should consider both illumination levels and exposure duration. This study analyzes temporal changes in pupil size under decreasing illuminance and proposes an entrance lighting design approach. The design and operating guidelines for domestic underground roadways and tunnel lighting are reviewed, and a controlled darkroom experiment is conducted with 12 experienced drivers. Illuminance is reduced in stages to represent access, threshold, transition, and interior zones, with reference to expressway tunnel lighting operating guidelines. Pupil diameter is measured using a wearable eye tracker. The results show that the pupil diameter increased from 1.77 to 3.44 mm and stabilized after approximately 60 s. Based on this response, a lighting scheme is proposed for a design speed of 100 km/h, thus retaining the existing threshold-zone length and illuminance levels while extending the distances over which successive transitionzone illuminance levels are maintained. The findings provide an empirical basis for incorporating the temporal characteristics of pupil responses into entrance lighting designs. However, pupil stabilization should not be equated with complete dark adaptation across visual functions. Further experiments under the proposed lighting conditions, along with visibility and driving behavior assessments in actual road environments, are required to validate this scheme.