Noise Level Analysis of Major Construction Machinery
This study examined the utilization patterns of major types of construction equipment at construction sites in Korea and evaluated the noise characteristics associated with their operation. It also assessed how equipment-generated noise may affect both workers at construction sites and residents in nearby communities. The findings showed that the hydraulic breaker produced the highest noise level, reaching 101.5 dB(A). Such a high noise level indicates that breaker operations may significantly contribute to noise propagation beyond site boundaries and may increase the likelihood of complaints from nearby residents. These results provide quantitative evidence for understanding construction-equipment noise and may serve as useful reference data for establishing effective noise-control measures, improving relevant regulations, and developing construction-site noise management policies.