논문 상세보기

Experimental Study on Seismic Performance of Base-Isolated Bridge KCI 등재

  • 언어ENG
  • URLhttps://db.koreascholar.com/Article/Detail/6312
구독 기관 인증 시 무료 이용이 가능합니다. 4,000원
한국지진공학회 (Earthquake Engineering Society of Korea)
초록

Base isolation is an innovative design strategy that provides a practical alternative for the seismic design of structures. Base isolators, mainly employed to isolate large structures subjected to earthquake ground excitations and to rehabilitate structures damaged by past earthquakes, deflect and absorb the seismic energy horizontally transmitted to the structures. This study demonstrated that the base isolation system may offer effective performance for bridges during severe seismic events through shaking table tests. Two base isolation systems using laminated rubber bearings with and without hydraulic dampers are tested. The test results strongly show that the laminate rubber bearings cause the natural period of the bridge structure increased considerably, which results in the deck acceleration and the shear forces on the deck acceleratino and the shear forces on the piers reduced significantly. The results also demonstrate that the hydraulic dampers enhance the system's capacity in dissipating energy to reduce the relative displacement between the bridge deck and the pier.

저자
  • Chung Woo jung(Daewoo Engineering Company)
  • Yun Chung Bang(Department of civil Engineering)
  • Kim Nam Sik(Hyundai Institute of Construction Technology)
  • Seo Ju Won(Hyundai Institute of Construction Technology)