간행물

Journal of the Earthquake Engineering Society of Korea KCI 등재 한국지진공학회논문집

권호리스트/논문검색
이 간행물 논문 검색

권호

제30권 제6호(통권 제174호) (2026년 11월) 6건

1.
2026.11 구독 인증기관 무료, 개인회원 유료
김민준, 박진완, 유경환, 송현섭
This study investigates the seismic isolation transmission characteristics and develops a regression-based model for predicting the acceleration demand of internal equipment mounted within electrical cabinets subjected to Uniform Hazard Spectrum (UHS)-based seismic excitations. Shake table experiments were conducted using four UHS scale factors—0.5, 1.0, 1.5, and 2.0—under both isolated and non-isolated conditions. The cabinet reference response was defined as the maximum acceleration recorded among all cabinet measurement points, while the envelope response for internal equipment locations was determined as the greater response between two monitored internal locations. Experimental results revealed that the acceleration response of internal equipment typically exceeded that of the cabinet reference, suggesting that reliance solely on cabinet measurements may underestimate the seismic demand on internal components. Although seismic isolation at the cabinet base was effective in mitigating the cabinet reference response, this attenuation was not equivalently observed in the internal equipment. The residual transmission ratio demonstrated that, even after isolation, internal equipment experienced a relatively higher acceleration compared to the cabinet reference. These findings indicate that cabinet base isolation alone is insufficient to substantially reduce the seismic response of internal equipment. Furthermore, a log-log regression analysis identified input intensity and isolation condition as significant predictors for internal equipment acceleration demand within the experimental range. The study concludes that, to ensure the protection of internal components, cabinet base isolation should be complemented by targeted local vibration reduction measures for internally mounted equipment.
4,000원
2.
2026.11 구독 인증기관 무료, 개인회원 유료
김현호, 박지훈
This study conducts a comprehensive evaluation of the seismic response of a lead-acid battery rack system installed within a telecommunication data center, utilizing advanced three-dimensional analytical models. Nonlinear modeling was employed to accurately capture the principal load-transfer mechanisms, including battery sliding, spacer-to-battery contact, and baseplate-to-slab interactions. The seismic analyses encompassed response-spectrum as well as both linear and nonlinear time-history approaches, with seismic input parameters aligned with the Korean technical standards for broadcasting and telecommunications facilities. The investigation addressed the influences of damping methodology, support restraint conditions, analytical method, installation location, and spacer representation. Results indicated that linear analyses tended to overestimate demands on key structural members and connections relative to nonlinear analyses. Notably, in the nonlinear analyses, the phenomena of battery sliding and spacer contact were found to modify the load-transfer mechanism, thereby reducing the overall rack response while amplifying localized responses, particularly in the X-direction guardrail. Furthermore, while lower installation locations generally exhibited reduced seismic responses, the degree of reduction varied across structural members and connections due to the complex nature of nonlinear battery–rack interactions.
4,300원
3.
2026.11 구독 인증기관 무료, 개인회원 유료
김태은, 박지훈
This paper provides a detailed case study evaluating the seismic capacity of two representative non-seismic low-rise lightweight steel structures in Korea, specifically located on site class S3. The first structural model was developed based on standard design documentation, while the second incorporated structural attributes identified via a comprehensive survey of actual building construction practices. The seismic performance of both models was assessed using linear analysis and nonlinear static analysis methodologies. For each analytical approach, the effective peak ground acceleration (EPGA) of the demand response spectrum was progressively increased until the analytical model reached the limit state as defined by the relevant procedure. The critical factor influencing seismic capacity in both cases was the welded beam-to-column connection at the column tops. Results demonstrated that the seismic capacities required to prevent collapse ranged from 1.3 to 1.4 g under linear analysis, but reduced significantly to between 0.55 and 0.94 g under nonlinear static analysis. This discrepancy is primarily attributable to uncertainties associated with the response modification coefficient in the linear analysis, as well as the explicit consideration of post-yield behavior and deformation capacities of welded connections in the nonlinear assessment.
4,000원
4.
2026.11 구독 인증기관 무료, 개인회원 유료
김재영, 박지훈
This study provides a comprehensive analysis of the principal factors influencing the seismic capacity of non-seismic steel factory buildings in Korea. The investigation evaluated the impacts of column base-connection modeling, design wind load, design crane load, and site class, utilizing effective peak ground acceleration as the principal index of seismic capacity. Analytical models that incorporated the rotational stiffness and moment resistance of exposed column base connections exhibited limitedly enhanced seismic performance relative to those employing idealized pinned-base assumptions. While the inclusion of design crane loads resulted in increased member cross-sections, its influence on overall seismic capacity was comparatively minor. In contrast, elevated design wind-load levels led to substantial increases in member sizes, thereby augmenting both the lateral stiffness and strength of the structural system, and consequently improving the seismic capacity of the buildings. Site class was also found to be a significant determinant, as variations in soil stiffness altered seismic demand, with softer soil conditions yielding lower effective peak ground acceleration values. Among all parameters considered, modifications in structural member dimensions and properties associated with design wind-load levels were identified as the most influential for enhancing seismic capacity within the scope of this study.
4,000원
5.
2026.11 구독 인증기관 무료, 개인회원 유료
정성훈, 장원석, 이정한, 윤누리
Korea’s Earthquake Disaster Response System currently estimates building damage and casualty figures by applying ground motions computed on a 2 km grid to building statistics aggregated at the administrative district level. While operationally efficient, this methodology lacks the spatial resolution necessary to assess damage at the level of individual facilities, produces discontinuities across grid boundaries, and complicates both data updating and model replacement. In response to these limitations, this paper introduces a geographic information system (GIS)-based earthquake damage estimation platform that adopts individual buildings as the fundamental unit of analysis, developed in collaboration with the National Disaster Management Research Institute. The system manages a nationwide database encompassing approximately eight million buildings, sourced from the national building register, and assigns building-specific fragility functions based on registered structural attributes. Seismic ground motion, damage, and casualty estimates are computed on a per-building basis, with the ability to aggregate results at any spatial scale specified by the user. The platform’s default configurations replicate those of the existing system; however, attenuation relationships, site characterization data, ground motion amplification models, and fragility parameters can be flexibly modified. Analytical outputs are accessible through iterative computational runs, spreadsheet reports, and interactive web map visualizations. The paper summarizes verification efforts against the current system, as well as a case study reproducing the 2017 Pohang earthquake. Four application scenarios on the Pohang testbed—sensitivity to seismic source parameters and model selection, comparison of site database alternatives, identification of high-risk structures, and targeted damage prediction for critical facilities such as schools and police stations—illustrate the enhanced informational value that building-level estimation adds confers for disaster response and preparedness. Comparative analysis with international systems clarifies the distinctive features of the proposed approach.
4,600원
6.
2026.11 구독 인증기관 무료, 개인회원 유료
조정래, 이상호, 윤혜진, 이진호, 이동섭
The displacement-pressure formulation of fluid-structure interaction (FSI) in liquid storage tanks frequently results in nonsymmetric system matrices characterized by real eigenvalues. This research investigates the application of the load-dependent Ritz (LDR) method to the time-history analysis of such nonsymmetric systems, systematically assessing its accuracy and computational efficiency relative to direct integration (Direct) and the conventional eigenmode-based modal analysis approach (Modal). Comprehensive seismic response analyses were conducted for two liquid storage tanks featuring free surfaces and varying aspect ratios. The Modal closely replicated the Direct integration results but required a substantial number of eigenmodes to achieve convergence. By contrast, the LDR method constructed a significantly smaller, excitation-dependent basis, thereby reducing the computational cost of basis generation and overall analysis time, while still accurately reproducing the peak responses of mid-height hydrodynamic pressure, base shear, and overturning moment. However, diminished accuracy was observed in scenarios dominated by long-period sloshing effects, particularly for tanks with extended sloshing periods. These findings demonstrate that the LDR method constitutes a computationally efficient alternative for impulse-dominated time-history analyses of nonsymmetric tank FSI systems, provided that careful consideration is given to basis size selection, center frequency, and the incorporation of low-frequency components when long-period sloshing responses are non-negligible.
4,000원