검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 96

        1.
        2023.11 구독 인증기관·개인회원 무료
        The first commercial operation of Kori-1, which commenced in April 1978, was permanently shut down in June 2017, with plans for immediate dismantling. The decommissioning process of nuclear power plants generates a substantial amount of radioactive waste and poses significant radiation exposure risks to workers. Radioactivity is widely distributed throughout the primary coolant system of the reactor, including the reactor pressure vessel (RPV), steam generator (SG), and pressurizer. In particular, the SG has a considerable size and complex geometry, weighing approximately 326 tons and having a volume of 400 m3. The SG tubes are known to contain high levels of radioactivity, leading to significant radiation exposure to workers during the dismantling process. Therefore, this study aims to evaluate the workers’ radiation exposure during the cutting of SG tubes, which account for approximately 95% of the total radiation dose in the SG. Firstly, the CRUDTRAN code, developed to predict the behavior of soluble and particulate corrosion products in a PWR primary coolant system, is used to estimate the radioactive inventory in the SG tubes. Based on decontamination factors (DF) obtained in the SG tubes through overseas experience, the expected reduction in radioactivity during the Kori-1 reactor’s full-system decontamination (FSD) process is considered in the CRUDTRAN results. These results are then processed to estimate the radioactivity in both the straight and bent sections of the tubes. Subsequently, these radioactivity values are used as inputs for the MicroShield code to calculate the worker radiation exposure during the cutting of both straight and bent sections of the tubes. The cutting process assumes that each SG tube section is cut in a separate, shielded area, and the radiation exposure is assessed, taking into account factors such as cutting equipment, cutting length, working hours, and working distance. This study evaluates the worker radiation exposure during the cutting of SG tubes, which are expected to have a significantly high radioactivity due to chalk river unidentified deposit (CRUD). This assessment also considers the reduction in radioactivity within the steam generator tubes resulting from the FSD process. Consequently, it enables an examination of how worker radiation exposure varies based on the extent of FSD. This study may provide valuable insights for determining the scope and extent of the FSD process and the development of shielding methods during the dismantling of SG tubes in the future.
        2.
        2023.11 구독 인증기관·개인회원 무료
        South Korea’s first commercial nuclear reactor, Kori Unit 1, was permanently shut down in 2017, and preparations are currently underway for its decommissioning. After the permanent shutdown, the spent nuclear fuel from the reactor core is removed and stored in a spent fuel storage facility. Subsequently, steps are taken for its permanent disposal, and if a permanent disposal site is not determined, it is stored in an interim storage facility (or temporary storage facility). Therefore, the activation criteria for radiation emergency plans vary depending on the movement of spent nuclear fuel and the storage location. In this study, it reviewed emergency plans in the U.S. NRC Regulatory Guide (Draft) titled ‘Emergency Planning for Decommissioning Nuclear Power Reactors’ to determine the requirements for radiation emergency plans needed for decommissioned nuclear power plants. Additionally, by examining emergency plans applied to decommissioning nuclear power plants in the United States, this study identified emergency plan requirement that could be applicable to future decommissioned nuclear power plants in South Korea. This study will contribute to the establishment of appropriate radiation emergency plans for decommissioning nuclear power plants in Korea for providing accurate information on overseas cases and relevant guidelines.
        3.
        2023.11 구독 인증기관·개인회원 무료
        In 2017, the permanent shutdown of Kori Unit 1 was decided, marking the initiation of preparations for the decontamination and decommissioning of Kori Unit 1. The dismantling of radiologically contaminated equipment and concrete structures such as the Reactor Vessel (RV), Reactor Vessel Internals (RVI), and the Bio shield is crucial in the nuclear decommissioning process. These components became radiologically contaminated due to nuclear fission reactions occurring in the reactor during its operational period. The RVI dismantling at Spain’s Jose Cabrera Nuclear Power Plant involved the use of mechanical saws and disk cutters to divide it into approximately 430 pieces, taking 16 months to complete. Germany’s Stade Nuclear Power Plant employed mechanical circular saws to segment their RVI into about 170 pieces, which took 30 months to accomplish. Meanwhile, the RVI at Germany’s Wurgassen Nuclear Power Plant was subdivided into approximately 1,200 pieces using a combination of mechanical saws and abrasive water jets, requiring 61 months for completion. Due to the radioactivity in Kori Unit 1’s Reactor Vessel (RV) and Reactor Vessel Internals (RVI), remote-controlled systems were developed for cutting within the cavity to reduce radiation exposure. Specialized equipment was developed for underwater cutting operations. This paper focuses on modeling related to RVI operations using the MAVRIC code. The upper and lower parts of the RVI are classified as low-level radioactive waste, while the sides of the RVI that come into contact with fuel are classified as intermediate-level radioactive waste. Therefore, the modeling presented in this paper only considers the RVI sides since the upper and lower parts have a minimal impact on radiation exposure. Accurate calculations were performed through geometric modeling and radiation dose modeling. These research findings are anticipated to contribute to enhancing the efficiency and safety of nuclear reactor decommissioning operations
        4.
        2023.11 구독 인증기관·개인회원 무료
        In nuclear power plant (NPP) decommissioning, ventilation and purification of the building atmosphere are important to create a working environment, ensure worker safety, and prevent the release of gaseous radioactive materials into the environment. The heating, ventilation, and air conditioning (HVAC) system of each building is maintained, modified, or newly installed. In this study, based on APR1400, operation strategies were presented in case of ventilation abnormalities in the reactor containment building (RCB), where highly radioactive particles and high dust are most frequently generated during NPP decommissioning. For research, it was assumed that the entire RCB atmospheric ventilation during decommissioning would use the RCB purge system of the existing NPP and perform continuous ventilation. Additionally, it is assumed that areas where high radiation particles and high dust occur locally, such as reactor containers or internal segments, are sealed with tents and purified using a HEFA filter of a temporary portable HVAC, and a exhaust flow path is connected to the discharge duct of the existing RCB purge system. The possibility of abnormal occurrence was largely divided into two cases. First, when large amounts of uncontrolled pollutants are released into the atmosphere inside the RCB, discharge to the environment is stopped manually or automatically by a modified engineered safety function activation signal (ESFAS). Afterwards, the RCB purge system should be operated in recirculation mode to sufficiently purify the RCB atmosphere with a HEPA filter. Second, when the first train of the low volume purge system is not running due to a failure, standby train should be operated. If both low volume purge trains fail, a high volume purge system is used. Intermittent purge operation is preferred due to large capacity during high volume purge operation. In cases where it is not possible to operate all purge systems due to common issues such as power supply, atmospheric sampling is performed to determine whether to proceed with the work inside RCB.
        5.
        2023.11 구독 인증기관·개인회원 무료
        Kori Unit 1, pressurized water reactor, is the Korea’s first commercial nuclear power plant. It successfully generated electricity for a period of 30 years, commencing from April 19, 1978. Following its approval for continued operation in 2008, Kori Unit 1 continued to operate for an additional 9 years, resulting in a total operational period of 39 years. On June 18, 2017, Kori Unit 1 was permanently shut down. Since then, Korea is actively preparing for the decommissioning of nuclear power plant. During the decommissioning of a nuclear power plant, the heavy components such as reactor, steam generator, pressurizer, reactor coolant pump located in the containment building should be taken out of the containment building. To take out heavy components from the containment building, pipes connected to heavy component should be cut. There are numerous pipes connected to the heavy component, each with varying dimensions and material. Each pipe has a different level of contamination depending on its use. In this study, optimal cutting method of pipe connected to steam generator, one of the heavy components of nuclear power plant, is proposed during the decommissioning of Kori unit 1. In case of pipe connected to Kori unit 1 steam generator, material is stainless steel or carbon steel. These pipes have varying inner diameter, ranging from 0.6 cm to 74 cm, and thickness ranging from 0.15 cm to 7.1 cm. These pipes are classified as low and intermediate level waste (LILW) or very low level waste (VLLW). Because characteristics of pipes are different, each pipe optimal cutting methods are proposed differently considering material, dimension, contamination level, cutting cost, cutting time, and the management of secondary waste. As a result, the cutting method for pipe of reactor coolant system is selected to orbital cutting. The cutting method of main steam pipe and main feedwater pipe is selected to oxygen cutting. In case of other small pipes, cutting method is selected to circular saw.
        6.
        2023.11 구독 인증기관·개인회원 무료
        In general, radioactive waste with high radioactivity is made into a solid form with performance such as leaching restriction, shape retention, and structural stability so that radioactive waste does not affect humans and the environment as much as possible. This should be applied equally to radioactive waste, whether homogeneous or heterogeneous. The requirements are stipulated in the “Low and Intermediate Level Radioactive Waste Delivery Regulations” notice of the Korea Nuclear Safety and Security Commission. On the other hand, the waste acceptance criteria for domestic disposal facilities require immobilization of heterogeneous waste when the activity concentration is above a certain level, but do not provide specific immobilization performance requirements. In this study, the immobilization requirements applied to heterogeneous radioactive waste in various overseas countries operating low and intermediate-level radioactive waste disposal facilities were studied. First, the IAEA’s safety standards for radioactive waste immobilization, domestic regulations, and disposal facility waste acceptance criteria were reviewed. Countries operating surface disposal facilities such as the United States, France, Spain, and Japan and countries operating underground disposal facilities such as Sweden and Finland were divided to review the current status of immobilization application to heterogeneous waste in overseas countries. When reviewing overseas cases, each country’s disposal methods, types of disposal waste, and waste treatment criteria were also reviewed. It was found that the immobilization requirements for heterogeneous radioactive waste vary depending on the disposal method and the type of barrier used to ensure disposal safety in each country. The common point is to surround heterogeneous radioactive waste within a concrete lining of a certain thickness, and to apply the thickness, compressive strength, and diffusion coefficient of the concrete lining as immobilization performance requirements. Through this study, the immobilization performance requirements for heterogeneous radioactive waste in various overseas countries that stably operate low- and intermediate-level radioactive waste were confirmed, which is expected to contribute to specifying the performance requirements for immobilization of heterogeneous radioactive waste in domestic disposal facilities.
        7.
        2023.11 구독 인증기관·개인회원 무료
        Due to the saturation of spent fuel pool of nuclear power plant in Korea, temporary storage for spent fuel will be installed, and spent fuel will be stored and managed in dry cask for a considerable period of time. Since spent nuclear fuel must withstand continuous decay heat, radiation and high internal pressure of the fuel rod in the cask, behavior of spent nuclear fuel is needed to be reviewed. Spent nuclear fuel used in Pressurized Water Reactor (PWR) in Korea is stored in a wet storage currently, but it is going to store a temporary dry-storage facility on Kori site. Therefore, it is very important and meaningful to evaluate the behavior of nuclear fuel with realistic modeling. Also, domestic PWR nuclear fuel has various burn-up. In the past, the burn-up of nuclear fuel in light water reactors was low, but in order to increase power generation efficiency, the concentration of uranium was increased and the number of new fuel was increased. Therefore, a large amount of nuclear fuel with burn-up of 45,000 MWD/MTU or higher, generally called high burn-up, is also stored in the spent fuel pool (SFP). Therefore, it is necessary to evaluate by dividing three different burn-up such as, low, medium, and high burn-up. Thus, this study will review the behavior of nuclear fuel at different burn-up during the temporary storage period with FALCON (EPRI), computational code and analyze the factors affecting the integrity of nuclear fuel, including when the temporary storage is extended its additional lifetime. And this evaluation will contribute developing the spent fuel management plan in Korea.
        8.
        2023.09 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        United States Nuclear Regulatory Commission (U.S. NRC) specifies regulations on obtaining licenses and describes the technical position on the average waste concentration, also known as Concentration Averaging and Encapsulation Branch Technical Position (CA BTP); CA BTP helps classify blendable waste and discrete items and address concentration averaging. The technical position details are reviewed and compared in a real environment in Korea. A few cases of concentration averaging based on the application of CA BTP to domestic radioactive waste are presented, and the feasibility of the application is assessed. The radioactive waste considered herein does not satisfy the Disposal Concentration Limit (DCL) of the second-phase disposal facility while applying the preliminary classification. However, if CA BTP is applied when the radioactive waste is mixed with other radioactive waste items in a large and heavy container, it can be disposed of at the second-phase disposal facility in Gyeongju Repository. To apply the CA BTP of the U.S. NRC, it is necessary to investigate the safety assessment conditions of the US and Korea.
        4,200원
        9.
        2023.06 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        To broaden the utilization of nuclear energy, uranium as a fuel should be mined indispensably. Mining accounts for the largest portion of the cost of producing the uranium assembly. Therefore, this study analyzes the trends of uranium prices, which have a significant impacts on the mining cost. Uranium production contributing to the price fluctuations is explained in five periods from 1945 to the present. Moreover, the series of events affecting uranium prices from the 1970s until the present are verified. Among them, the most recent incidents considered in this study are the following: COVID-19 pandemic, Kazakhstan unrest, and Russia-Ukraine war. European countries have started to reconsider the transition to nuclear power to reduce their dependence on Russian oil and gas, which has contributed to the surge in uranium prices. Based on the results of this study, various international issues have been closely associated with the nuclear power industry and uranium, affecting the production of uranium and its price.
        4,000원
        10.
        2023.06 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        According to NSSC Notice No. 2021-10, safety analysis needs to be introduced in the decommissioning plan. Public and occupational dose analyses should be conducted, specifically for unexpected radiological accidents. Herein, based on the risk matrix and analytic hierarchy process, the method of selecting accident scenarios during the decommissioning of nuclear power plants has been proposed. During decommissioning, the generated spent resin exhibits relatively higher activity than other generated wastes. When accidents occur, the release fraction varies depending on the conditioning method of radioactive waste and type of radioactive nuclides or accidents. Occupational dose analyses for 2 (fire and drop) among 11 accident scenarios have been performed. The radiation doses of the additional exposures caused by the fire and drop accidents are 1.67 and 4.77 mSv, respectively.
        4,000원
        11.
        2023.06 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        The potential impact of hypothetical accidents that occur during the immediate and deferred dismantling of the Kori Unit 1 steam generator has been comprehensively evaluated. The evaluation includes determining the inventory of radionuclides in the Steam Generator based on surface contamination measurements, assuming a rate of release for each accident scenario, and applying external and internal exposure dose coefficients to assess the effects of radionuclides on human health. The evaluation also includes calculating the atmospheric dispersion factor using the PAVAN code and analyzing three years of meteorological data from Kori NPP to determine the degree of diffusion of radionuclides in the atmosphere. Overall, the effective dose for residents living in the Exclusion Area Boundary (EAB) of Kori NPP is predicted, an it is found that the maximum level of the dose is 0.034% compared to the annual dose limit of 1 mSv for the general public. This implies that the potential impact of hypothetical accidents on human health discussed above is within acceptable limits.
        4,000원
        12.
        2023.05 구독 인증기관·개인회원 무료
        Most of the spent nuclear fuel generated by domestic nuclear power plants (NPPs) is temporarily stored in wet storage which is spent fuel pool (SFP) at each site. Currently, in case of Kori Unit 2, about 93.6% of spent nuclear fuel is stored in SFP. Without clear disposal policy determined for spent nuclear fuel, the storage capacity in each nuclear power plant is expected to reach saturation within 2030. Currently, the SFP stores not only spent fuel but also various non-fuel assembly (NFA). NFA apply to all device and structures except for fuel rods inserted in nuclear fuel assembly. The representative NFA is control element driving mechanism (CEDM), in-core instrument (ICI), burnable poison, and neutral resources. Although these components are irradiated in the reactor, they do not emit high-temperature heat and high radiation like nuclear fuel, so if they are classified as intermediate level waste (ILW) and low level waste (LLW) and moved outside the SFP, positive effects such as securing spent fuel storage space and delaying saturation points can be obtained. Therefore, this study analyzes the status of spent fuel and Non Fuel Assembly (NFA) storage in SFP of domestic nuclear power plants. In addition, this study predict the amount of spent fuel and NFA that occur in the future. For example, this study predicts the percentage of current and future ICIs and control rods in the SFP when stored in the spent fuel storage rack. In addition, the positive effects of moving NFA outside the SFP is analyzed. In addition, NFA withdrawn from SFP is classified as ILW & LLW according to the classification criteria, and the treatment, storage, and disposal methods of NFA will be considered. The study on the treatment, storage, and disposal methods of NFA is planned to be conducted by applying the existing KN-12 & KN-18 containers and ILW & LLW containers being developed for decommissioning waste.
        13.
        2023.05 구독 인증기관·개인회원 무료
        The current storage capacity of the spent nuclear fuel at the Kori unit 2 has reached approximately 94% saturation, excluding emergency core capacity. As South Korea has not yet constructed any interim storage facilities to store spent nuclear fuel, one of possible options is to install high density storage racks in spent fuel pool at the reactor site to increase its capacity. The high density storage rack is a technology developed to allow the storage to have more spent nuclear fuel than originally planned, while still ensuring safety. It achieves this by reducing the storage gap between the spent nuclear fuel. The purpose of this study is to investigate an appropriate storage capacity for spent fuel pool in the Kori unit 2 and the factors to be considered during the high density storage rack installation. Given that the Kori unit 2 is planning continued operation and Korea Hydro & Nuclear Power (KHNP) is preparing to install a temporary storage facility for spent nuclear fuel at the Kori nuclear site, it is reasonable to consider the installation of high density storage racks in the spent fuel pool as a storage solution for these issues. When evaluating the capacity of the spent fuel pool, the amount of spent nuclear fuel generated by other reactors in Kori nuclear site and the amount of spent nuclear fuel generated by continued operation of the Kori unit 2 should be taken into account. This study aims to consider these factors and evaluate the capacity of the spent fuel pool. Furthermore, when installing high density storage rack for the spent nuclear fuel, it should be noted that the existing storage racks at the Kori unit 2 are welded to the liner plate, which may require additional cutting work. Therefore, it is necessary to review the suitable method for the cutting work. Additionally, assuming that divers need to access the area near the storage racks or cutting & welding devices require radiation protection in the area, it is essential to analyze the expected radiation level with computational code and propose appropriate measures to limit work time or establish a work zone. Thus, this study evaluates appropriate capacity of spent fuel pool and work methods for the installation of high density storage rack in the spent fuel pool at the Kori unit 2. It is expected that this paper contributes to install high density storage racks in SFP safely.
        14.
        2023.05 구독 인증기관·개인회원 무료
        A radiation shielding resin with thermal stability and high radiation shielding effect has been developed for the neutron shielding resin filled in the shielding shell of dry storage/transport cask for spent nuclear fuel. Among the most commercially available neutron shielding resins, epoxy and aluminum hydroxide boron carbide are used. But in case of the resin, hydrogen content enhances the neutron shielding effect through optimization of aluminum hydroxide, zinc borate, boron carbide, and flame retardant. We developed a radiation shielding material that can increase the boron content and have thermal stability. Flame retardancy was evaluated for thermal stability, and neutron shielding evaluation was conducted in a research reactor to prove the shielding effect. As a result of the UL94 vertical burning test, a grade of V-0 was received. Therefore, it was confirmed that it had flame retardancy. According to an experiment to measure the shielding rate of the resin against neutron rays using NRF (Neutron Radiography Facility), a shielding rate of 91.54% was confirmed for the existing resin composition and a shielding rate of 96.30% for the developed resin composition. A 40 M SANS (40 M Small Angle Neutron Scattering Instrument) neutron shielding rate test was performed. Assuming aging conditions (6 hours, 180 degrees), the shielding rate was analyzed after heating. As a result of the experiment, the developed products with 99.8740% and 99.9644% showed the same or higher performance.
        15.
        2022.12 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        When decommissioning nuclear power plant (NPP), the first task performed is cost estimation. This is an important task in terms of securing adequate decommissioning funds and managing the schedule. Therefore, many countries and institutions are conducting continuous research and also developing and using many programs for cost estimation. However, the cost estimated for decommissioning an NPP typically differs from the actual cost incurred in its decommissioning. This is caused by insufficient experience in decommissioning NPPs or lack of decommissioning cost data. This uncertainty in cost estimation can be in general compensated for by applying a contingency. However, reflecting an appropriate standard for the contingency is also difficult. Therefore, in this study, data analysis was conducted based on the contingency guideline suggested by each institution and the actual cost of decommissioning the NPP. Subsequently, TLG Service, Inc.’s process, which recently suggested specific decommissioning costs, was matched with ISDC (International Structure for Decommissioning Costing)’s work breakdown structure (WBS). Based on the matching result, the guideline for applying the contingency for ISDC’s WBS Level 1 were presented. This study will be helpful in cost estimation by applying appropriate contingency guidelines in countries or institutions that have no experience in decommissioning NPPs.
        4,000원
        16.
        2022.10 구독 인증기관·개인회원 무료
        Nuclear power plants decommissioning is planned to be started in middle of the 2020. It is necessary to develop safety evaluation and verification technology during decommissioning to ensure the safety of security monitoring measures and maintenance measures, appropriate emergency plans and preparations for decommissioning, and the use of proven engineering when establishing decommissioning plan. For this purpose, a nuclear power plant decommissioning plan is prepared in several stages before decommissioning. When a lifetime of a nuclear power plant has reached, it needs to be decommissioned and therefore operator company should submit decommissioning plans to the National Safety and Security Commission. And safety analysis should be included in this document and it is explained in chapter 6. According to the NSSC Notice No. 2021-10, it is largely divided into principles and standards, exposure scenarios, dose assessment, residual radioactivity, abnormal events, and risk analysis. When unexpected radiological accident is happened, both public and occupational dose analysis should be conducted. However, research on the former can be found easily on the other hands, research on the latter is not active. In this paper, method of choosing scenarios of accidents during the decommissioning the nuclear power plants is briefly introduced. Accidents during nuclear power plants decommissioning cases in USA is chosen and its risk is evaluated by using risk matrix and ranked by AHP method. During the decommissioning phases, varieties of radioactive waste is expected to be generated such as contaminated concrete and metal. On the other hand, Dry Active Waste (DAW) is generated and its amount is and its amount is 7,353 drums. Characteristic of DAW is highly flammable compared to concrete or metal. Moreover, depending on method of radioactive waste conditioning and type of radioactive nuclides, release rate of the nuclides varies. Thus this type of radioactive waste is critical to fire accidents and such accident can occur extra dose exposure which exceeds the guideline of the regulatory body to workers. Therefore, in this paper, occupational dose exposure during the fire accident is conducted.
        17.
        2022.10 구독 인증기관·개인회원 무료
        Reactor pressure vessels and steam generators generated in the process of dismantling nuclear power plants or replaced steam have various shape and occupy a considerable amount of the disposal site when disposed of in original shape. For the development of domestic technologies related to the disposal of large wastes, it is necessary to secure technologies for reducing large radioactive metal wastes, including technologies such as decontamination, cutting, melting, and residual radioactivity evaluation. Cases of disposal of steam generators in Europe and the United States were investigated. Except for u-tubes, steam generators are less contaminated or easily decontaminated, so it is possible to reduce the volume of waste subject to final disposal by exempting a significant amount through appropriate treatment. Korea Hydro & Nuclear Power Co. is currently temporarily storing 24 steam generators at 41.6 billion won. This paper presents a method to exempt more parts of the steam generator and reduce the volume of waste by properly combining mechanical cutting thermal cutting and melting to dispose of the steam generator. Currently the decontamination and dismantling industries of nuclear facilities are gradually expanding around the world. Therefore, it is necessary to localize the treatment technology for metal waste generated during maintenance and dismantling. The result of this study can be used to establish waste reduction and disposal method for dismantling steam generators.
        18.
        2022.10 구독 인증기관·개인회원 무료
        The Korean administration assumed that the amount of low and medium level waste generated during the decommissioning of nuclear facilities in Korea was 14,500 drums (based on 200 L) and designed the LILW repository accordingly. Accordingly, it is necessary to separate the nuclear power plant decommissioning waste into clearance waste by mobilizing means such as decontamination and cutting as much as possible, and to deregulate it together with non-radioactive waste. As a result, clearance waste and non-radioactive waste are dominated by concrete and metal, and it is necessary to evaluate how to recycle them. Many existing studies have conducted research on each recycling method, and accordingly, it can be judged that the technological maturity is sufficient. Accordingly, we would like to propose a method for comprehensive management and evaluation of concrete. By applying the decision matrix proposed in IAEA TRS No. 401, it will be possible to compare the 5 factors (cost, technical feasibility, risk, availability of disposal, and full cycle impact). However, in the case of concrete, if the existing construction waste recycling methodologies are fully used, the technical feasibility can be considered equal. Therefore, it was judged that it would be good to introduce the aspect of public acceptance as an evaluation item instead of technical feasibility. The amount of waste that can be generated when decommission a nuclear power plant is only insignificant compared to the total amount of waste concrete that is generated during the year. Accordingly, one option is to fully integrate the waste concrete recycling system and utilize it for road construction. Next, it is possible to suggest the option of recycling in the construction of shields in the nuclear industry, as suggested in previous studies, and the method of using it as a backfill material such as for a decommissioned NPP site or other sites. As an example, and a draft stage, this study was evaluated based on existing studies after all options were equally weighted. When the profit and loss was evaluated in a way that a maximum of 5 points were given to each option, the case of using it as a backfill in various applications was evaluated as the best option. Unlimited recycling, such as road construction, was evaluated to be highly damaging in terms of public acceptance.
        19.
        2022.10 구독 인증기관·개인회원 무료
        3D modeling is a technology for representing real objects in a virtual 3D space or modeling and reproducing the physical environment. 2D drawings for viewing the existing building structure have limitations that make it difficult to understand the structure. By implementing this 3D modeling, specific visualization became possible. 3D technology is being applied in a wide range of preevaluation work required for nuclear decommissioning. In Slovakia, 3D modeling was applied to determine the optimal cutting strategy for the primary circuit before dismantling the VVER type Bohunice V1. In Japan, the Decommissioning Engineering Support System (DEXUS) program has been developed that incorporates VRDose, a decommissioning engineering support system based on 3D CAD models. Through this, the cutting length of the work object and the quantity of containers for packaging waste are calculated, exposure dose calculations in various dismantling scenarios, and cost estimation are performed. Korea also used 3D technology to evaluate the decommissioning waste volume for Kori Unit 1 and to evaluate the optimal scenario of the decommissioning process procedure for the research reactor Unit 1. 3D technology is currently being used in various pre-decommissioning evaluations for VVER, PWR, and research reactors. Overseas, a program that matches various decommissioning pre-evaluation tasks with cost estimation has also been developed. However, most 3D technologies are mainly used as a support system for dose evaluation and amount of decommissioning waste calculation. In this study, 3D modeling was performed on the PHWR structure, and physical and radiological information about the structure was provided. The information on the structure can present the unit cost for the work object by confirming the standard of the applied unit cost factor (UCF). The UCF presents the unit cost for repeated decommissioning operations. The decommissioning cost of the work object can be obtained by multiplying the UCF by the number of repetitions of the work. If the results of this study are combined with the process evaluation and waste quantity estimation performed in previous studies, it is judged that it will be helpful in developing an integrated NPP decommissioning program that requires preliminary evaluation of various tasks. In addition, it is judged that a clear cost estimation of the object to be evaluated will be possible by matching the 3D work object with the UCF.
        20.
        2022.10 구독 인증기관·개인회원 무료
        Radioactive waste is classified into Intermediate level, low level, and very low potential based on the amount of radioactivity per unit gram, that is, the concentration limit. This method of classifying radioactivity per unit weight is not a problem if all packaged wastes are homogeneous. However, the reality is that not all waste is homogeneous. Relative hotspots may exist. Also, when several items are mixed, if one item has a relatively higher concentration than other items, it can become a relative hotspot. In Korea, even if all nuclides in a single radioactive waste package satisfy the low level concentration limit, if even one nuclide exceeds the concentration limit, the radioactive waste package becomes the intermediate level. In case of the United States, the US NRC provides regulations related to obtaining license as well as presents the technical position on the average waste concentration called Concentration Averaging and Encapsulation Branch Technical Position (CA BTP). CA BTP classifies waste into four types : Blendable Waste, Encapsulated items, Single Discrete Items, and Mixture of Discrete Items, and presents each approach to concentration averaging. In general, this is a method that suggests an acceptable ratio in case of the waste, which relatively high concentration waste is mixed. In order to apply this in Korea, we compare the classification standards for low and Intermediatelevel waste in Korea and the United States, related laws and backgrounds, and the application methods of CA BTP.