검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 8

        1.
        2024.03 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        Glutamate-mediated oxidative stress causes neuronal cell death by increasing intracellular Ca2+ uptake, reactive oxidative species (ROS) generation, mitogen-activated protein kinase (MAPK) activation, and translocation of apoptosis-inducing factor (AIF) to the nucleus. In the current study, we demonstrated that corydaline exerts potent neuroprotective effects against glutamate-induced neurotoxicity. Treatment with 5 mmol/L glutamate increased cellular Ca2+ influx, ROS generation, MAPK activation, and AIF translocation. In contrast, corydaline treatment decreased cellular Ca2+ influx and ROS generation. Western blot analysis revealed that glutamate-mediated MAPK activation was attenuated by corydaline treatment. We further demonstrated that corydaline treatment inhibited the glutamate-mediated translocation of AIF to the nucleus. We propose that corydaline is a promising lead structure for the development of safe and effective neuroprotectants.
        4,000원
        2.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        해사영어는 선박 운항, 해양 안전, 선내 의사소통 및 선외 교신을 위해 설계된 특수한 영어 언어체계이다. 국제해사기구 STCW(선원의 훈련, 자격증명 및 당직근무의 기준에 관한 국제협약)에 따르면 국제항해에 종사하는 항해사가 되기 위해서는 SMCP를 포함한 해사영어 대한 충분한 이해가 수반되어야 한다. 본 연구는 음성인식, 번역, 단어 기입 등 유형의 해사영어시험을 통하여 학생들 의 해사영어 활용 능력을 측정하고 플랫폼 사용에 따른 시험 점수 향상 정도, 나아가 초임항해사로 나가기 위하여 요구되는 해사영어 시험 플랫폼 활용 시간 등을 조사하고자 하였다. 실험은 먼저 초기 시험을 통해 학생들의 일반영어능력과 SMCP 활용 능력에 대한 연 관성을 조사한 후, 중간 시험 및 최종 시험을 통해 플랫폼 활용에 대한 점수 향상 정도, 응시시간 변화 등 요인을 측정하였다. 초기 시 험을 통해 개인 요인(예: 토익 점수, 본인 스스로에 대한 영어능력 평가)에 따른 그룹 간 해사영어시험 점수에 유의한 차이가 있음을 확인하였으며, 중간시험 및 최종시험을 통해 플랫폼 활용이 유의한 시험점수 향상으로 이어졌음을 확인하였다. 해당 연구는 해사 교육 분야에 다양하게 적용할 수 있는 학습 플랫폼 활용 효능을 조사하였으며 향후 해사영어 교육 외 그 범위를 넓혀 활용될 수 있을 것으 로 사료된다.
        4,000원
        5.
        2018.10 구독 인증기관·개인회원 무료
        소나무재선충병의 나무주사는 살선충제를 중심으로 실시되어 왔으며, 매개충인 솔수염하늘소와 북방수염하늘소의 방제는 주로 항공방제나 지상방제를 통하여 이루어졌다. 본 연구에서는 나무주사를 통하여 매개충 (솔수염하늘소)을 방제하기 위한 연구로 Abamectin+Acetamiprid ME, Thiamethoxam DC 약제의 나무주사시 솔수염하늘소의 약효발현농도, 처리 후 기간별 효과(2017년~2018년)를 검토하였다. 실내 발현농도 시험에서는 Acetamiprid, Thiamethoxam LC50 value는 각각 0.102ppm, 0.083ppm 으로 나타 났으며, 야산(포장)에서 Abamectin+Acetamiprid ME, Thiamethoxam DC 처리구의 100.0% 치사 소요일 수는 처리 90일 후 11.0일, 9.4일, 처리 360일 후 11.6일, 10.0일로 나타나서 두 약제 모두 3월 처리시 다음해에 발생하는 매개충 (솔수염하늘소) 방제까지 가능함을 확인 할 수 있었다.
        6.
        2010.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was performed to investigate the effects of Needle Electrode Electrical Stimulation(NEES) on ischemia-induced cere˗ brovascular accidents. After obstruction and reperfusion of arteries in white mice, the amounts of necrosis and inflammation related sub˗ stances Bax, IL-6, Caspase-3, and COX-2 were measured in neurons of the fore-brain. The following results were obtained. This study used 21 male specific pathogen free(SPF) SD rats, 8 weeks of age and approximately 300g in weight. Each exposed artery was completely occluded with non-absorbent suture thread and kept in that state for 5 minutes. The sutures were then removed to allow reperfusion of blood. Test group is control group(common carotid artery occlusion models), a GI(underwent common carotid artery occlusion), and NEES(underwent NEES after artery occlusion). The GI and NEES groups were given 12, 24, or 48 hours of reperfusion before NEES. NEES device(PG6, ITO, Japan, 9V, current, 2Hz) was used to stimulate the bilateral acupoint ST36 of the SD rats for 30 minutes while they were sedated with 3% isoflurane. An immuno-his˗ tochemistry test was done on the forebrains of the GI induced rats. Both Bax and Caspase-3 immuno-reactive cells, related to apoptosis, were greater in the GI than the NEES group. Cox-2 and IL-6 immuno-reactive cells, related to inflammation, were greater in the GI and NEES groups than the control group. We can expect that applying NEES after ischemic CVA is effective for preventing brain cells from being destroyed. And we can conclude NEES should be applyed on early stage of ischemic CVA.
        4,000원
        7.
        2016.10 서비스 종료(열람 제한)
        Background : Bitter gourd (Momordica charantia) is a vegetable with pantropical distribution and contains the active ingredient, such as momordicine and charantin. Moreover, bitter gourd has been reported to exhibit antidiabetic, anticancer, cardiovascular-protective and antioxidant effects. But, the distinctive bitter taste of bitter gourd was not suitable for food preference. This study was conducted to evaluate the improvement effects of bitter taste of bitter gourd with natural fermentation and roasting process. Methods and Results : Bitter gourd fruits were obtained from Headeulnyeokae Co., Ltd.(Gang-Jin 59253, Repubilc Korea). Fruits of bitter gourd were prepared by natural fermentation process for 4h at 25℃. After natural fermentation, the fruits were dried in hot-air dryer for 15h at 49-55℃. The dried fruits were roasted in 500 g batches at 120℃ for 10 min in the electric rotisserie oven. After roasting, fruit pieces were extracted with hot water and cold water. One of them was cool-type, and the other was hot-type bitter gourd tea. In the sensory evaluation, hot tea and cold tea showed the high scores on color, flavor and overall acceptability. Conclusion : These mean that roasted bitter gourd had less bitter, and it could be utilized widely as drink and food material.
        8.
        2005.01 KCI 등재 서비스 종료(열람 제한)
        Several samplers using gravimetric methods such as high-volume air sampler, MiniVol portable sampler, personal environmental monitor(PEM) and cyclone were applied to determine the concentrations of fine particles in atmospheric condition. Comparative evaluation between high-volume air sampler and MiniVol portable sampler for PM10, and between MiniVol portable sampler and PEM was undertaken from June, 2003 to January 2004. Simultaneously, meteorological conditions such as wind speed, wind direction, relative humidity and temperature was measured to check the factors affecting the concentrations of fine particles. In addition, particle concentrations by cyclone with an aerodynamic diameter of 4 ㎛ were measured. Correlation coefficient between high- volume air sampler and portable air sampler for PM10 was 0.79 (p<0.001). However, the mean concentration for PM10 by high-volume air sampler was significantly higher than that by MiniVol portable sampler (p=0.018). Correlation coefficient between Minivol portable sampler and PEM for PM2.5 was 0.74 (p<0.001), and the measured mean concentrations for PM2.5 did not show significant difference. Difference of the measured concentrations of fine particle might be explained by wind speed and humidity among meteorological conditions. Particle concentration differences by measurement samplers were proportional to the wind speed, but inversely proportional to the relative humidity, though it was not a significant correlation.