        검색결과 33

        1.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study tested the effect on the toxicity of formaldehyde to select a shelter site due to formaldehyde leakage. As a result of the experiment, the range of ERPG-2 and 3 is between 2.2km and 9.6km, ASET is 6 minutes at 1km, 15 minutes at 3km, 22 minutes at 5km, and the lethality rate is 99.9% at 1km and 9% at 3km. In areas where refuge time is less than 15 minutes or the lethality rate is more than 2%, a shelter is installed. This is because if there are only a few evacuees, the evacuation time may take longer than the pre-movement time of 15 minutes or less specified in PD 7974-6:2004, and the lethality rate with the lowest number of deaths was calculated to be 2%. The shelter must be equipped with a hepa-filter, positive pressure equipment, air purifier, air respirator, goggles, chemical protective clothing type 4 and sufficient parking space must be secured to ensure the safety of evacuees.
        4,500원
        2.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to identify psychological anxiety factors related to firefighters' field activities and suggest improvement measures. To investigate the actual status of psychological anxiety factors, a survey was conducted on approximately 3,500 current firefighters, and the responses of 505 people who participated in the survey were analyzed. As a research method, frequency analysis and cross-analysis were conducted according to the general characteristics of the participants to determine the actual level of psychological anxiety in each work field and the results were analyzed. As a result of the analysis, it was statistically confirmed that firefighters feel a lot of psychological burden due to legal and institutional inadequacies during dispatch, return, or field activities, and frequent friction with civil servants is also a major cause of psychological anxiety. Therefore, based on the results of this study, it is proposed to establish a permanent legal support team in each city and province, designate and operate a hospital dedicated to psychological treatment, and establish a special provision for traffic accidents during the return of fire trucks so that firefighters can concentrate on their duties without psychological anxiety. do.
        4,200원
        3.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to propose measures to increase evacuation safety by calculating the habitable time using a fire and evacuation simulation program for the Room-escape cafe currently in operation, and comparing and analyzing it with the evacuation required time. Assuming a fire due to overheating of electric heaters in use in front of the warehouse, the habitable time was calculated through fire simulation, and the occupant's evacuation time calculated through evacuation simulation according installation of safety facilities, etc. was compared and analyzed with the habitable time. In the case of escape room cafes with safety facilities installed, evacuation safety was satisfied, but in escape room cafes without safety facilities, the evacuation safety was not secure. As a result of analyzing evacuation safety for each scenario based on the ASET analyzed in the fire simulation, it was found that in scenario 1, evacuation safety was secured and everyone successfully evacuated, while in scenario 2, no one succeeded in evacuation. These results can be said to confirm that the installation of safety facilities is very important in business establishments such as escape room cafes, which become enclosed structures when games are started.
        4,000원
        4.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study analyzed and identified various causes of caustic alarms of 163 fire detectors that occurred from January 2019 to December 2021 at domestic semiconductor manufacturing plants equipped with about 30,000 fire detectors, and proposed a new non-fire prevention cause investigation plan by applying the NFPA 921 scientific methodology. The results of the study are as follows. First, in terms of necessary recognition and problem definition, an analog detector and an integrated monitoring system were proposed to quickly determine the location and installation space information of the fire detector. Second, in order to prevent speculative causes and errors in various analyses in terms of data analysis and hypothesis establishment, non-fire reports were classified into five by factor and defined, and the causes of occurrence by factor were classified and proposed. Finally, in terms of hypothesis verification and final hypothesis selection, a non-fire prevention improvement termination process and a final hypothesis verification sheet were proposed to prevent the cause from causing re-error.
        4,000원
        5.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to verify the impact of a metaverse-based safety education program on the fire safety awareness of elementary school students. Utilizing the National Fire Agency's 119 metaverse program, an educational program was implemented for two months, and the experimental group was examined using paired-sample t-tests, while comparisons with the control group were made using independent-sample t-tests. The results revealed statistically significant differences between the experimental and control groups in the area of fire prevention. Although no statistically significant differences were observed over time within each group, the overall average scores for the entire class improved across all areas. Based on these findings, the effectiveness of metaverse-based safety education is suggested; however, a significant difference compared to traditional education was not detected. The study concludes by exploring implications for considerations in the implementation of metaverse safety education in the future.
        4,000원
        6.
        2023.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In piping systems, trapeze hangers are subjected to vertical and horizontal seismic loads and stiffeners are used. In this study, monotonic compression tests were conducted with the removable stiffeners using three variables: stiffener clamp fixing position, section length, and installation direction. The maximum load reinforced with stiffeners could withstand a compressive load of 11kN by applying a safety factor of 10%. It could be estimated that the fixing clamp spacing or the length of shape and load had a proportional relationship. And the stiffener must be fixed in the direction of the strong axis on hinge parts. Also the stiffener buckiling load design proposes to use a method of calculate the flexural buckling compressive strength of and unreinforced full threaded bolt.
        4,000원
        7.
        2023.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to understand the current status of exemptions for traffic accidents during the return of emergency vehicles and to provide suggestions for improvement. A survey was conducted on 3,500 firefighters to investigate the perception of traffic accidents during the return of emergency vehicles, and responses from 505 participants were analyzed. Based On the demographic characteristics and perception of the participants, frequency analysis and variance analysis were used as research methods to analyze basic statistics and the current situation. The results showed that firefighters have concerns and anxieties about traffic accidents during the return of emergency vehicles, and the need for applying exemptions and enacting explicit legal provisions was statistically confirmed. Based on these results, we suggest a policy for exemptions to improve the preparation for re-deployment and to alleviate the concerns and anxieties of firefighters.
        4,500원
        8.
        2023.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Social welfare facilities are used by a wide range of local residents, including vulnerable populations such as the elderly, children, and people with disabilities. During emergencies like fires, confusion can arise as these individuals try to evacuate. Evacuation simulation results have shown that utilizing evacuation systems based on specific evacuation scenarios can significantly decrease the time required for evacuation compared to general evacuation procedures. By anticipating potential fires based on changes in social and facility environments, appropriate evacuation scenarios can be developed and applied to evacuation systems, thus contributing to the safety and security of individuals during emergencies. In conclusion, for social welfare facilities that serve a large number of people, it is necessary to expand the focus on performance-based design depending on the size of the facility, and to continuously develop and train for appropriate evacuation scenarios that align with changing facility environments.
        4,000원
        9.
        2023.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to measure sedimentation status change with the changes in internal pressure for dry chemical extinguishers of various use periods and analyze the suitability of the fire extinguishers' performance criteria. When the internal pressure of the fire extinguisher is 0%, 2 out of 10 new dry chemical powders for the 5 elapsed years were noted to be suitable, including 3 recycled dry chemical powders with 5 elapsed years that were found eligible. One out of 10 new dry chemical powders for 10 elapsed years was shown as suitable. Also, one new dry chemical powder for 13 elapsed years was suitable. When the internal pressure of the fire extinguisher was 50%, all 10 out of 10 new dry chemical powders for 5 years, recycled one with 5 elapsed years, and a new one with 10 elapsed years were found to be suitable, while 9 new dry chemical powders for 13 years were shown as suitable. When the internal pressure of the fire extinguisher was normal, new ones with 5 elapsed years, recycled ones with 5 elapsed years, new ones with 10 elapsed years, and new ones with 13 elapsed years were all 10 out of 10 samples noted as suitable. In summarizing the experiment results, it was found that the sedimentation status, one of the fire extinguisher's physical properties experiments, affects the fire extinguisher's performance criteria rather than the change with use periods.
        4,000원
        10.
        2023.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to compare and analyze the flame retardant performance of Japanese cypress(Chamaecyparis obtusa) plywood, commonly used in indoor decoration, furniture, and tableware, by treating it with three different fire retardants with different primary ingredients. The experiment was conducted in compliance with Article 31, Paragraph 2 of the Enforcement Decree of the Fire Facilities Installation and Management Act and Articles 4 and 7-2 of the Flame Retardant Performance Standards. After flame time, after glow time, char length, and char area were measured. As a result, first, after flame time was measured at 0 seconds regardless of whether the flame retardant treatment was applied. Second, after glow time was relatively long, measuring 22.7 seconds without treatment, which is likely due to the weak fire resistance and high concentration of carbon monoxide generated by the chemical characteristics of the Japanese cypress itself. Third, it was confirmed that the effects of the primary ingredient, phosphorus, in the flame retardant treatment varied depending on the technological development of the manufacturers of the same species of Japanese cypress plywood. In the future, it is expected that the results of this study will provide fundamental data to select flame retardant treatments that show high flame retardant performance according to the botanical characteristics of the wood.
        4,000원
        11.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In school safety education, it was difficult to apply how to link the safety education according to grades year, and student’s interest was reduced due to the repetition of existing safety education contents and the absence of new teaching methods and tools. In this study, as a new type of safety education, a performance forms fire safety education program was developed. This program aims to increase students’ interest and satisfaction in safety education, and to this end, it was connect with korean elementary science curriculum and combined various engineering teaching materials or tools and methods. Developed program was applied to 2,231 students, 25 schools in 10 regions of Gyeonggi-do and surveyed 476 fifth and sixth grade students program satisfaction and 3 factors of interest in fire safety education who could respond to the survey. As a result of applying the program, more than 90% of students responded more than 'satisfied' in all areas. and statistical test(independent t-test and non-parametric test) indicates over-all satisfaction and interest factors in the program are high regardless of gender and grade, so the effectiveness can be guessed indirectly and there is a universal applicability also. Moreover, examining the influence of student interest level in the satisfaction of the fire safety program, it was found that in order to increase the satisfaction of fire safety education, students should have more fun with the content and feel interest in the teacher's teaching method or explanation.
        4,000원
        12.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study collected powder extinguishers with 6-10 years of elapsed life from January 2012 to January 2017 in market, factory, and apartment areas to experiment with changes in fineness and to examine the characteristics of extinguishing power. First, in the case of ABC powder, 98.3 wt% of the 8-year market area and 98.6 wt% of the 10-year apartment complex were found to be inappropriate in the first, second, and third arithmetic average analysis of the powder extinguisher from 6 to 10 years. That is, the fine distribution and size of the powder extinguishing agent particles should be managed within an appropriate range. It is analyzed that the powder fire extinguisher may experience a change in the fineness of the powder depending on the external environment exposure, placement, management status, and age of use, resulting in a decrease in digestive power or inability to radiate. Second, the fire extinguisher cannot be used in the initial fire suppression depending on the place of deployment, the environment of deployment, the progress of the number of years of use, and maintenance, so it is necessary to strengthen the device that enables fire extinguisher maintenance and inspection. Third, in the manufacturing process, the charging method should also be reviewed in consideration of the conditions of the workplace, the humid season, and the rainy environment.
        4,000원
        13.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, according to the staking method of the fire hose in the indoor hydrant system, the number of kinks when the fire hose is deployed was measured and analyzed to examine how the staking method of the fire hose affects the kink when the hose is deployed. The fire hose staking method was classified into three types: donut-type, accordion-type, and hose hanger-type, and the walking speed and number of kinks were measured by repeating the experiment 5 times for male and female students. The results of the study are as follows. (1) Among the three types of fire hose staking methods, the donut-type staking method had an average of 92 times for male students and 86 times for female students on average. (2) The accordion-type and hose hanger-type staking methods showed similar results with an average of one or two kinks for both male and female students. (3) Regardless of the staking method, it was found that in general, male students with high walking speed had more kinking than female students with slow walking speed.
        4,000원
        14.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study is to check waterproof by number of twists of fire hose and measure the first waterproof time to analyze the relationship between twists of fire hose and first waterproof time and waterproof by position of twists so as to suggest the efficient plan to prevent twists of fire hose. Ordinary fire hose did not make waterproof in case that position of twists was near the nozzle with twists 5 times or more, while anti-twist fire hose had no problem for waterproof only with delayed time. Like ordinary fire hose, anti-twist fire hose also showed the tendency to increase the waterproof time in proportion to the number of twists. In case that the position of twists was near waterproof port even with 10 times of twists in anti-twist fire hose, the first waterproof time was increase by 0.63 seconds on average without any problem for waterproof, which was somewhat faster than that in ordinary fire hose. With respect to the position of twists, waterproof of anti-twist fire hose was affected more as the number of twists was increased more near the nozzle rather than near the waterproof port, like ordinary fire hose. In summary, anti-twist fire hose equipped with anti-twist tool at the middle connection port and the nozzle showed a good waterproof performance with delayed waterproof time regardless of number of twists, as a solution for the twist problem of ordinary fire hose.
        4,000원
        15.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objective of this study was to understand which type of fire hose should be placed in indoor fireplug box upon analyzing the preparation time between rack-type fire hose and reel-type one. With respect to the type of hose, rack-type stacking method was used and hose preparation time was measured with 5 times of repeat test, separating men and women. Study results reveal that preparation time of reel-type fire hose took longer than that of rack-type one in both men and women. For both rack-type hose and reel-type hose, preparation time by two persons took shorter than that by one man. Also, preparation time by three persons took shorted than that by two women. Preparation time for both rack-type hose and reel-type one by men took shorter than that by women. In summary, it was confirmed that rack-type hose could be prepared within shorter time than reel-type one. Since the size of drum set in the reel-type fire hose is relatively small, it had some difficulty in preparation of fire hose timely.
        4,000원
        16.
        2021.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the purpose of this study was to examine the effect of twisting in the preparation of waterproofing in the process of unfolded donut-type staking method fire hoses in indoor hydrant system. The central pull-out method caused more twisting than the rolling method, and there was no significant difference in the number of twists according to the pull-out method in the case of male and female students. It was found that the time it took to untwist and prepare waterproofing was much shorter for male students. The angle valve and hose are connected, and the time to untwist and prepare for waterproofing after withdrawing the fire hose with the hose and nozzle connected was shorter than the unconnected state. In the rolling method, when a hose connected with two 15 m fire hoses was used and the angle valve-hose was connected, but the hose-nozzle was not connected, the least kinking occurred. The time to untwist and prepare for waterproofing was also the shortest. As a result, in the withdrawal method of the donut-type loaded fire hose in the indoor hydrant system, it is a rolling method rather than a central withdrawal method. With the angle valve and hose connected, unfold the fire hose with the hose and nozzle connected, if a large number of people unwind the twisted hose, the time to prepare for waterproofing can be shortened.
        4,000원
        17.
        2021.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study developed a scenario to understand the reaction rate and operational time according to RTI value of rate of rise detector in each type in case of fire mattress. In the results of analyzing the reaction rate and operational time of detector in each scenario, in case when installing a single detector, the elevated temperature per minute was raised to 8℃/min ~ 9℃/min. In case when installing two detectors, it was raised to 9℃/min ~ 10℃/min. In case when installing three detectors, it was raised to 10℃/min. The horizontal distance between detector and mattress was 1.8m~2.5m. Whenever the number of detectors was increased, the horizontal distance was decreased. The operational time of detector was within maximum 540 seconds and minimum 420 seconds. As the research tasks in the future, there should be the researches on the effects of reaction rate of detector on the evacuation in case of fire through the result value of RSET by setting up the latency until the detector operates, and the researches on the safety by understanding if the operational time of detector is suitable for the evaluation standard of performancecentered design.
        4,000원
        18.
        2021.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study analyzed the physical changes in 119 paramedics transporting equipment at the emergency site and performing post-cardiopulmonary resuscitation through experiments. First, the average heart rate increased by about 25 times comparing CPR was performed without physical load and with personal protective equipment after moving equipment. In the third quartile, it increased to about 27 times. Second, when CPR was performed without physical load, and CPR was performed after moving the equipment with personal protective equipment, both the body temperature was raised and the rising body temperature was measured within normal body temperature. Third, the change in respiration rate increased by 7 times on average comparing CPR was performed without physical load and CPR was performed after moving the equipment while wearing personal protective equipment. In the third quartile, it increased to about 11 times. Finally, the change in blood pressure increased by 26.6 mmHg on average comparing CPR was performed without physical load and with wearing personal protective equipment after moving the equipment, and increased by 31.2 mmHg on average in the third quartile.
        4,000원
        19.
        2020.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to determine the correlation between the apartment resident community and housing satisfaction and suggest which factors can contribute to improving the local community’s housing environment and satisfaction by means of the local inhabitants and apartment residents participating in co-managing the community. The study results are as follows. Firstly, the apartment resident community had a positive effect on housing satisfaction but the effects were insignificant. This revealed that residents’ interest in communicating with the resident community was low due to various organizations such as the women’s association, election committee, and autonomous society being used as means to pursue personal gain rather than the development of the entire apartment. Secondly, the vitalization of the apartment resident community had a positive effect on housing satisfaction. The analysis results showed that the higher the level of unity and volunteering activities of residents, the more improved the resident vitalization programs are being managed, and the higher the level of resident participation, the higher the housing satisfaction. Lastly, this study suggests the supplementation and upgrading of apartment community facilities into complex community facilities as a means to unify the residents and vitalize the resident community. To vitalize the resident community and strengthen the community spirit, the residents will need to voluntarily create a community hub by forming community-tailored associations and programs through connections with local governments and businesses.
        4,000원
        20.
        2020.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to find the causal relationship between the effects of apartment inhabitants’ life management and administrative management on housing satisfaction. The study results are as follows. Firstly, life management showed to have a positive effect on life satisfaction. In other words, the better the management of public order and facilities, the higher the satisfaction of housing satisfaction. Thus, the principal agent of management needs to increase inhabitants’ housing satisfaction through education and training on developing life management techniques. Secondly, administrative management showed to have a positive effect on life satisfaction. Thus, the more accurate the completion documents and management transfer process necessary for administrative management, the higher the cost-cutting effects of accounting, construction, and service contracts, the more transparent the resident agreement process in accordance with management policies, the more transparent the election process of building representatives and resident representatives, and the higher the effects of energy saving, the higher the housing satisfaction of inhabitants. This revealed that the principal agent of management needs to increase housing satisfaction through education and training on developing administrative management techniques because the level of administrative management had a positive effect on housing satisfaction. As a result, in order to create reliability between inhabitants and the principal agents of management, the transparency of administrative management such as document disclosure must be ensured, thus improving the housing satisfaction of inhabitants.
        4,000원