        검색결과 3

        1.
        2002.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 하퇴의지 착용자와 정상 성인간의 시간-거리, 운동형상학 변수를 조사하고 비교하기 위하여 실시하였다. 연구 대상자는 외상으로 인한 하퇴 절단자로서 내골격식 하퇴의지를 착용하고 독립적으로 보행이 가능한 20명과 연령, 신장으로 짝짓기한 대조군(matched control group) 20명이 참여하였다. 보행분석은 Vicon Clinical Manager Software (VCM)를 내장한 PC에 5개의 카메라가 연결되어 있는 Vicon 512
        4,000원
        2.
        2001.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to compare the static pressure, dynamic pressure, dynamic pressure-time integral, relative impulse, and contact time between the sound lower limb and amputated lower limb in trans-tibial amputee subjects using Parotec system. Seventeen trans-tibial amputee subjects wearing endoskeletal trans-tibial prosthesis voluntarily participated in this study. The results were as follows: 1) In static standing condition, there were significantly higher static pressure in sound lower limb insole sensor of 10, 14, 15, 18, 19, 23, and 24 and in amputated lower limb insole sensor of 9, 12, and 16 (p<.05). 2) In dynamic gait condition, there were significantly higher dynamic pressure in sound lower limb insole sensor of 2, 18, 22, 23, and 24 and in amputated lower limb insole sensor of 5, 9, 10, 11, 12, 14, 15, and 16 (p<.05). 3) In dynamic gait condition, there were significantly higher pressure-time integral in sound lower limb insole sensor of 2, 4, 18, 19, 20, 21, 23, and 24 and in amputated lower limb insole sensor of 5, 11, 12, and 15 (p<.05). 4) In dynamic gait condition, there were significantly higher relative impulse in sound lower limb insole sensor of 18, 19, 20, 22, 23, and 24 and in amputated lower limb insole sensor of 5, 9, 10, 11, 12, and 15 (p<.05). 5) In dynamic gait condition, there was significantly higher percentage of contact time in push off phase of sound lower limb and in support phase of amputated lower limb (p<.05). These results suggest that trans-tibial amputee subjects had characteristics of shortened push off phase due to unutilized forefoot and of lengthened support phase with higher pressure in the midfoot.
        4,000원
        3.
        2001.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to investigate the effect of donning of a hard insole in patients with hallux valgus. Fourteen subjects were selected from patient with foot pain at Lee Chang-Heon Foot Clinic from August 4, 2000 to September 15, 2000. The hallux valgus angle and the first-second intermetatarsal angle were radiographically measured before and after donning the hard insole. Based on these two kinds of angles, a mild hallux valgus deformity group was characterized by the hallux valgus angle of less than 20 degrees, and a moderate hallux valgus deformity group was characterized by the hallux valgus angle of 20 to 40 degrees. After three weeks with the hard insole donned, the foot angles of the patients with hallux valgus were measured again. The data were analyzed by Wilcoxon signed ranks test, and the following results were obtained: 1) After the trial, both mild hallux valgus deformity group and moderate hallux valgus deformity group demonstrated that the hallux valgus angles were significantly decreased. 2) After the trial, mild hallux valgus deformity group demonstrated that the first-second intermetatarsal angle was significantly decreased. 3) After the trial, moderate hallux valgus deformity group demonstrated that the first-second intermetatarsal angle was not significantly decreased. The above findings revealed that according to donning hard insole, the hallux valgus angles of mild and moderate hallux valgus deformity groups and the first-second intermetatarsal angle of mild hallux valgus deformity group were significantly decreased. The results of this study have some limitation for generalization due to the limited number of subjects. Further studies are needed to evaluate the effect of hard insole on hallux valgus with more precise laboratory equipments and measurements in patients with hallux valgus.
        4,200원