검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 9

        1.
        2014.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Since the collapse of historical masonry structures in Europe in the late 1990’s, the interests in understanding the long-term effect of masonry under sustained compressive stresses have increased. That requires combining the significance of time-dependent effects of creep with the effect of damage due to overstress to realize the evolution of cracks and then failure in masonry. Meanwhile, composite analysis of masonry columns was proven effective for realizing ultimate strength capacity of masonry column. In this study, a simplified mechanical model with step-by-step in time analysis was proposed to incorporate the interaction of damage and creep to estimate the maximum stress occurred in masonry. It was examined that the interaction of creep and damage in masonry can accelerate the failure of masonry.
        4,000원
        2.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Partially earth anchored (PEA) can improve the structural safety and economic feasibility of multiple span cable stayed bridge (CSB). The PEA-CSB can restrain axial compressive load acting on a tower and reduce the global buckling length of a stiffened girder. For these reasons, structural members subject to axial forces can be effectively utilized and material quantity required for a steel deck can be reduced to save construction cost. In this study, the PEA system was verified for its application on a multiple span CSB. The CSB is a four-tower multi-span bridge which has a main span length of 500 m. As high tensile stress was generated at the top of the bridge decks at the mid-span between two main columns, a hybrid deck system for enhancing the bridge deck sections was proposed. While the composite sections made of concrete and steel were used near to the main columns, steel sections were used at the mid-span between two main columns.
        4,000원
        3.
        2013.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study a hybrid safety barrier system consisting of steel rail and carbon fiber reinforced polymer (CFRP) post is considered. W hile CFRP post is selected for impact energy reflection due to its high strength, steel rail is selected for impact energy absorption due to its high ductility. A numerical model considering the elastoplastic behavior of steel is formulated to simulate the dynamic responses of the hybrid system subject to an impact load. A hybrid roadside guard rail system of steel rail and CFRP post is proposed and analyzed with a case study. The numerical model for the hybrid roadside guard rail system is used to find optimized design of the proposed hybrid system.
        4,000원
        4.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study presents the effectiveness of a composite structure at improving blast resistance. The proposed composite structure consists of carbon fiber reinforced polymer (CFRP) and steel layers. While CFRP layer is used for blast energy reflection due to its high strength, steel layer is used for blast energy absorption due to its high ductility. A dynamic model is used to simulate the elastoplastic behavior of the proposed composite structure subject to blast load. Considering the magnitude variations of a blast event, the probability of failure of each layer is evaluated using reliability analysis. By assigning design probability of failure of each layer in the composite structure, the thickness of layers is optimized. A case study for the design of CFRP-steel composite structure subjected to an uncertain blast event is also presented.
        4,000원
        5.
        2012.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study proposes flexural failure design criteria of continuous slabs enhanced by a hybrid system of fiber reinforced polymer (FRP) and ultra high performance concrete (UHPC). The proposed hybrid retrofit system is designed to be placed at the top surface of the slabs for flexural strengthening of the sections in both positive and negative moment zones. The enhancing mechanisms of the proposed system for both positive and negative moment regions are presented. The neutral axis of the enhanced sections in positive moment zone at flexural failure is enforced to be in UHPC overlay for preventing the compression in FRP. From this condition, a relationship between design parameters of FRP and UHPC is established. Although the capacity of the proposed retrofit system to enhance flexural strength and ductility is confirmed through experiments of one-way RC slabs having two continuous spans, the retrofitted slabs failed in shear. To prevent this shear failure, a design criteria of flexural failure is proposed.
        4,000원
        6.
        2016.04 서비스 종료(열람 제한)
        A standard design section of a FRP DSCT wind power tower supporting 3MW was suggested and designed through AutoDSCT and CoWiTA programs. The thicknesses of the FRP tubes were optimized and by using the parameters of designed tower, the performance of the new type wind tower was evaluated via FAST program.
        7.
        2015.02 서비스 종료(열람 제한)
        화재로 인한 건축물 구조부재의 파괴는 추가적인 경제적 손실과 인명피해를 가져오기 때문에 화재에 대한 구조부재의 안전성은 매우 중요하다. 화재에 노출된 철근콘크리트 구조부재의 경우, 부재의 열전도도에 따라 내부 온도가 상승하고 부재의 하중저항강도와 강성이 저하된다. 철근콘크리트 부재의 화재에 대한 구조성능 확보 여부는 일반적으로 표준화재실험을 통하여 입증한다. 콘크리트의 열전도도는 온도에 따라 변하기 때문에 20℃, 100℃, 200℃, 300℃, 400℃, 500℃, 600℃ 700℃, 800℃ 열적 정상상태의 콘크리트 블록을 이용하여 측정한다. 본 연구에서는 철근콘크리트 기둥의 화재에 대한 구조성능 확보 여부를 확인하기 위한 표준화재실험으로부터 얻어지는 열적 비정상상태의 일차원 온도분포 시간이력으로부터 콘크리트의 열전도도를 추출하는 방법을 제안하였다. 표준화재실험으로부터, 기둥의 표면에서 중심까지의 온도분포 시간이력을 얻었다. 콘크리트의 온도에 따른 열전도도 k(T)=α{(T/120)²-T/60+200}에 대하여 다양한 α값으로 온도분포 시간이력을 수치해석 하였고, 실험결과와 가장 오차가 작게 발생하는 α값을 결정하였다. 결정된 콘크리트의 온도에 따른 열전도도는 20℃, 100℃, 200℃, 300℃, 400℃, 500℃, 600℃ 700℃, 800℃ 열적 정상상태의 콘크리트 블록에서 측정된 콘크리트의 열전도도와 비교하였고, 제안된 수치해석에 의한 열전도도 산출방법이 유효함을 입증하였다.
        8.
        2015.02 서비스 종료(열람 제한)
        콘크리트의 배합에 있어서 포졸란 물질의 사용은 수화된 시멘트내의 칼슘 실리케이트 수화물을 증가시키고 미세 공극을 채워줌으로써 콘크리트의 투수성을 감소시킨다. 또한 콘크리트 내의 전체 염기량을 낮추어 알카리 골재반응에 의한 균열의 방지에도 효과가 있다. 본 연구에서는 포졸란 물질 중 반응성이 가장 우수한 나노실리카를 사용한 콘크리트 시멘트의 미세구조를 나노압입을 이용하여 분석할 것이다. 물질 표면의 경도를 측정하여 물질의 강도 및 강성을 파악하는 방법은 금속에 대하여 100여년간 수행되어 왔다. 콘크리트의 강도를 파악하는데 있어서도 슈미트 햄머를 이용하여 콘크리트의 표면경도를 측정하고 강도와 연관 짓는 방법이 널리 사용되고 있다. 나노압입 실험은 이러한 이론적인 배경을 바탕으로 나노 스케일의 압입 시험기를 사용하여 시멘트 페이스트를 구성하고 있는 미세구조의 기계적 특성을 파악하는 방법이다. 향후 콘크리트의 동결융해 실험, 알카리 골재 반응, 프리스트레스 강선과의 접착력 실험과 연계하여 균열에 대한 높은 내구성을 요구하는 콘크리트의 제작에 최적화된 나노실리카의 배합비를 산출하기 위한 기초연구로 사용될 것이다.
        9.
        2015.02 서비스 종료(열람 제한)
        2014년 국내에서 발생한 리조트 붕괴사고와 환풍구 붕괴 사고는 대형 인명 피해를 가져왔으며, 이로 인해 구조물 상시 안전점검의 필요성이 더욱 부각되었다. 특히, 강 구조물의 연결부는 파괴에 취약하므로 더욱 철저한 안전 관리가 필요하다. 사용 중 구조물의 안전을 보장하기 위하여 구조물 부재와 연결부의 응력상태를 파악해야 하지만, 기존의 비파괴 검사방법으로는 부재의 사용 중 응력상태를 파악하기 어렵다. 강재의 압입실험으로 강재의 응력상태를 파악할 수 있으며, 나노스케일의 압입실험은 마이크로 단위의 흔적만을 남기므로 비파괴 검사의 방법으로 사용될 수 있을 것이다. 본 연구에서는 용접모재(Weld Metal, WM), 열영향부(Heat Affected Zone, HAZ), 모재(Base Metal, BM)로 구성된 용접 연결부의 미세구조의 구성성분비를 나노압입을 사용하여 측정하는 방법을 제안하였다. 광학현미경을 이용하여 분석된 미세구조 구성성분비와 결과를 비교하였고, 제안된 방법이 유효함을 확인하였다. 향후 연구결과를 바탕으로 구조용강재 용접연결부의 응력상태에 따른 미세구조 특성 변화를 파악할 수 있을 것이고, 용접 연결부의 건전성을 판단하는 진단기술로 확장될 수 있을 것이다.