검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 1

        1.
        2022.10 구독 인증기관·개인회원 무료
        HANARO, a multi-purpose research reactor, uses a reflector as heavy water to obtain high neutron flux. Therefore, two ion exchangers were installed to manage the heavy water quality of the reflector system. The operator of HANARO manages it according to the limit value (Conductivity: less than 0.5 mS/m, pH: 5.5~6.5), and if the limit value is not satisfied, the resin must be replaced. The reflector system is in the enclosed structure and it is designed to delay the release of tritium to the outside. Tritium is produced by a nuclear reaction between neutrons and deuterium. Tritium is inhaled into the body in the form of water or vapor, which is likely to cause internal exposure problem. In addition, since tritium spreads to other regions, thorough management is required. Therefore, HANARO measures and manages tritium in Rx and RCI using the bubbler collection method. In this paper, the change in the behavior of tritium due to the replacement of the reflector ion exchanger resin was analyzed. Due to the increase in conductivity of the reflector, the ion exchanger resin was replaced on March 3, 2022. Therefore, the concentration of tritium was measured to be about 5 times higher than usual. It did not exceed the emission limit, and the concentration values of tritium is stably managed by constant monitoring and analysis.