검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 5

        1.
        2023.05 구독 인증기관·개인회원 무료
        A large amount of small and medium-sized metal waste is generated during the decommissioning of nuclear power plants (NPPs). Metal waste is mostly contaminated with low-level radioactive, so it needs decontamination for self-disposal and recycling. A large amount of Organic Decontamination Liquid Waste during decontamination will be generated. The generated organic liquid waste is low in concentration, so the decomposition efficiency is low in the decomposition process. A conditioning process is necessary to concentrate at a high concentration. For effective treatment for Organic Decontamination Liquid Waste, the composition of organic liquid waste and conditioning process were analyzed. Organic acids, metal ions, radioactive nuclides, surfactants, etc. are present in the Organic Decontamination Liquid Waste, and suspended solids are sometimes generated by various reactions. According to previous studies, the concentration of organic acids including surfactants obtained results from several tens of ppm to a maximum of 1,000 ppm, so the maximum value of 1,000 ppm was assumed. For the composition and total amount of metal ions, the average value (52.7wt% Fe, 16.3wt% Ni, 15.1wt% Cr, 15.9wt% Mn) of the distribution of metal species removed by the actual decontamination process is applied, and the total amount is 1,000 ppm was assumed. As for the radionuclides, only 60Co and 137Cs, which are expected to be mainly present, were considered, and 60Co was assumed to be 2,000 Bq/g and 137Cs to be 360 Bq/g by referring to the literature. The amounts of suspended solids were assumed to be 500 ppm by referring to the characteristics of the liquid waste generated in the decontamination process of the NPPs. Based on the estimated value, a reaction formula was established and a simulated Organic Decontamination Liquid Waste was prepared. As a result of measurement using an analysis device, the composition of the estimated and simulated Organic Decontamination Liquid Waste had similar values. The conditioning and treatment process largely consists of pretreatment, conditioning, decomposition processes. Organic Decontamination Liquid Waste goes through a pretreatment process to remove impurities with large particles. In the conditioning process, treated water that has passed through the UF/RO membrane system is discharged into the environment. At this time, Concentrated water goes through a decomposition process for processing the Organic Decontamination Liquid Waste, and is discharged to the environment through a secondary RO membrane system. The conditioning process is the low-concentration Organic Decontamination Liquid Waste in the UF membrane system is forming a micelles in an RO membrane system, concentrating it to a high concentration and then go through a recirculation process in the UF membrane system. An experiment was conducted to confirm whether the concentration of surfactants occurred during the conditioning process. As a result of the experiment confirmed that the highly concentrated surfactant formed micelles and was filtered out in the UF membrane system.
        2.
        2022.10 구독 인증기관·개인회원 무료
        Organic waste generated by small and medium-sized (S&M-sized) metal decontamination in NPP decommissioning. To lower the concentration of these organic substances for a level acceptable at the disposal site, the project of “Development of Treatment Process of Organic Decontamination Liquid Wastes from Decommissioning of Nuclear Power Plants” is being carried out. The conditioning and treatment process of organic liquid waste was designed. Also, the literature was investigated to make simulated organic liquid waste, and the composition of these waste was analyzed and compared. As the decontamination agent, organic acids such as EDTA, oxalic acid, citric acid are used. The sum of the concentrations of these organic materials was set to a maximum value of 1,000 ppm. The major metal ions of the decontamination liquid waste estimated are 59Fe, 51Cr, 54Mn, 63Ni, and the concentrations are respectively 527, 163, 161, 159 ppm. Additional major metal ions are 60Co, 58Co, 137Cs. 58Co is replaced by 60Co because it has the same chemical properties as 60Co. Unlike the HLW, the contamination level of S&M-sized metal in primary system was quite low, so 60Co is set to 2,000 Bq/g. Considering the contribution of fission and gamma ray dose constant, 137Cs was estimated to 360 Bq/g. Also, suspended solids of decontamination liquid waste were set at 500 ppm. Under these assumptions, the simulated organic liquid waste was made, and then organic substances and metal ions were analyzed with TOC analyzer and ICP-OES. The TOC analysis value was expected to 392 ppm in consideration of the equivalent organic quantity. the test result was 302 ppm. Some of organics appears to have been decomposed by acid. The values of metal ions (Fe3+, Cr3+, Mn2+, Ni2+) analyzed by ICP-OES are 139, 4, 152, 158 ppm, respectively. A large amount of Cr3+ and Fe3+ were expected to exist as ions, but they existed in the form of suspended solid. Mn2+ and Ni2+ came out similar to the expected values. The designed conditioning and treatment process is largely divided into pretreatment, conditioning, and decomposition processes. After collecting in the primary liquid waste storage tank, large particulate impurities and suspensions are removed through a pretreatment process. In the conditioning process, treated liquid waste passes through UF/RO membrane system, and pure water is discharged to the environment after monitoring. Concentrated water is decomposed in the electrochemical catalyst decomposition process, then this water secondarily passes through the RO membrane system and then discharged to the environment after monitoring. Through an additional experiment, the conditioning and treatment process will be verified.
        3.
        2022.10 구독 인증기관·개인회원 무료
        The number of nuclear power plants that are permanently shut down or decommissioned is increasing worldwide, and accordingly, research is being conducted on an appropriate method for disposing of radioactive waste generated during the decommissioning of nuclear power plants. In the case of waste liquid generated during the decommissioning of nuclear power plants, it is important not only to efficiently reduce waste but also to secure the suitability of disposal. One of the solidification treatment methods for radioactive waste is cement solidification, but since cement solidification has poor solidification properties and generates a large amount of waste, improvement activities have been pursued. This study aims to develop high-performance cement-based materials and solidification treatment technology for solidification of liquid radioactive waste generated during nuclear decommissioning in order to improve the problems of cement solidification treatment method. For the development of polymer cement, epoxy resin and polyamine/amide mixed type and general Portland cement were mixed in various ratios. The most appropriate mixing ratio was 4.5:2, which showed the highest compressive strength. A simulated waste liquid was prepared by referring to the preliminary decommissioning plan of Shin-Kori Units 5 and 6, and it was dried and made into granules. Polymer cement was injected into a drum filled with granules by vacuum pressure to prepare a waste form matrix. In the solidification process, granules made by drying the waste liquid were used, and the solidification agent was filled in between the granules, so the total volume of solid radwaste was reduced compared to the conventional cement solidification treatment method. As a result, the amount of waste decreased to about 1/3, and the volume reduction rate increased by about 2.2 times. The compressive strength of 3,243 psi was confirmed in the disposability performance test for the manufactured solid samples. The compressive strength after the thermal cycling test, irradiation test, microorganism test, and immersion test was 2,257 psi, 2,306 psi, 4,530 psi, and 2,263 psi, respectively, exceeding the acceptance criteria of 500 psi. The leaching index was 7~13, and no free standing water was generated.