        1.
        2014.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A voltammetric investigation of Au assay was conducted at a low cost, using Nafion and DNA immobilized on a graphite Pencil working electrode (NDP) with a black lead counter and reference. The following optimal parameters were found: 0.4 V amplitude, 500 Hz frequency, -0.7 V initial potential, and 0.015 V increment potential. These optimal conditions were also applied to sand obtained from the river site. The aforementioned technique is simpler and less costly compared to the common voltammetry and spectrophotometric methods.
        4,000원
        2.
        2013.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The diagnostic assay of calcium ion was sought using a modified sensor with square-wave stripping voltammetry (SWSV) and cyclic voltammetry (CV). In this study, simple graphite pencil was used as working, reference, and auxiliary electrodes. By coating the working electrodes with DNA, their sensitivity was very much improved, and good results were yielded. Moreover, clean seawater was used as an electrolyte solution instead of acid and base electrolytes to lessen the expenses involved in the experiment. The analytical optimum conditions were also examined. These conditions were attained at the low detection limit of 0.6ugL1. After that, the results were applied to drinking water of milk contain.
        4,000원
        3.
        2013.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The electrochemical analysis of silver ion was performed using cyclic voltammetry (CV) and square-wave (SW) stripping voltammetry, and electrode cell systems were fabricated with graphite pencil electrode (GE) of working, reference and counter electrodes. Also electrolyte was the use of sea water as electrolyte solutions instead of ionic controlled solutions. The optimum analytical conditions for the cyclic and stripping parameters were determined using GE. The results approached the microgram working ranges of SW(ug/L) and CV(ug/L) Ag, and the optimum conditions were applied to frog's tissue and the food samples.
        4,000원
        4.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Diagnosis with an ex-vivo gold sensor was done using a modified fluorine-doping sensor, and cyclic voltammetry (CV) redox potentials of 0.4 V anodic and -0.2 V cathodic were obtained. Both peak currents were optimized using square-wave (SW) stripping voltammetry, and an analytical working range of 10-80 ug/L SW was attained. The precision of the 10-mg/L Au was 0.765 (n=8) RSD under the optimum conditions, and the analytical detection limit approached 0.006 ug/L (S/N=3) with only a 60 sec accumulation time. The developed method was used to examine the mouse droppings for medicinal diagnosis.
        4,000원
        5.
        2012.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A investigation of electrochemical analysis of antibiotics Neomycin (C23H46N6O13) was searched using electrochemical square wave (SW) stripping and cyclic voltammetry (CV) using working sensor of the modified carbon nanotube combination electrodes, optimum diagnostic parameters were searched by anodic stripping, final conditions were attained to working range of 1.0-14.0 ng/L, detection limit (S/N) was found to be 0.6 ng/L. The developed method was discovered to be fitting in quality control in the food, pharmaceutical and other manufacturing sectors.
        4,000원
        6.
        2012.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Bio assay of mercury and cadmium ions were searched using voltammetric analysis using DNA doped carbon nanotube paste electrodes (DCP). The square-wave stripping voltammetryic optimized results indicated working ranges of 1-10.0 ngL-1 and 20-100 ugL-1, Hg(II) Cd(II) within an accumulation time of 120 seconds, in 0.1-M phosphate buffer solutions of pH 6.3. The relative standard deviations of 5 ngL-1 Hg(II) and Cd(II) that observed were 0.14 and 0.22% (n=12), respectively, using optimum conditions. The low detection limit (S/N) was pegged at 0.1 ngL-1 (4.9×10-11M) Hg(II) and 0.2 ngL-1 (1.77×10-10M) Cd(II). The developed methods can be applied to assays in biological fish kidneys and water samples.
        4,000원
        7.
        2011.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A voltammetric assay of phenol ions was investigated using three electrode systems of graphite pencil working, reference and counter electrodes. Under optimum analytical parameters, square wave stripping working ranges were attained at a mili range of 10~80 mg/L and a micro range of 20~90 ug/L using seawater electrolyte. The developed sensor was applied to tap water and the human body system of a smoker. It was found that the methods can be applied to in vivo fluid or medicinal diagnosis.
        4,000원
        8.
        2011.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Threelectrodes systems were used in stripping voltammetry (SW) and cyclic voltammetry (CV) instead of the expensive platinum and Ag/AgCl reference electrodes. Moreover, the electrolyte solution was used with deep seawater, which can reduce water pollution, is more eco-friendly, and has a lower cost. The analytical optimum parameters measured via CV and SW and with working ranges were obtained from 10 to 80 ug/L using fluorine immobilized on a graphite pencil electrode (FE). Under the optimum conditions, the analytical detection limit of 6.30 ug/LAu was obtained. The results of the study can be applied to diagnostic assay for natural minerals and human finger tissue.
        4,000원
        9.
        2010.12 KCI 등재 서비스 종료(열람 제한)
        Voltammetric diagnostics of pesticide thiram was studied in plant leafs in vivo fluid with DNA immobilized on a carbon nanotube electrode (DCE). Sensor properties of carbon nanotube (CE) and DNA immobilized nanotube were compared. DCE was more effective than CE in target detecting. The parameters such as pH strength, stripping accumulation, amplitude, and increment potential were examined to find the optimum condition for detection of pesticide thiram in a sesame leaf. The optimized conditions were as follows 550 Hz frequency, 0.15 V amplitude, 0.005 V increment potential, -1.2 V initial potential, 4.78 pH, 500 sec accumulation time. Under optimum condition, the detection limit of thiram was attained at 0.01ng/L.
        10.
        2010.08 KCI 등재 서비스 종료(열람 제한)
        The three electrode system was used to detect the pesticide fenitrothion (C9H12NO5PS. MW=277.24) using cyclic voltammetry (CV) and square wave anodic stripping voltammetry (SWASV). The working electrode was mercury immobilized on a carbon nanotube paste electrode (Hg-CNTPE). At the optimized condition, the limit of detection (LoD) was 0.6 ppt (2.16×10 -12 M), and the relative standard deviation was 0.035% (n=15). And there is more sensitive in detecting fenitrothion than common type carbon nanotube paste electrode. When it was implanted into the brain of live fish (carp), the existence of fenitrothion was measured without any destruction or damage of tissue.