검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 4

        1.
        2023.05 구독 인증기관·개인회원 무료
        The Korea Laboratory Accreditation Scheme (KOLAS) is the national accreditation body responsible for providing accreditation services to testing and calibration laboratories. The primary objective of KOLAS is to promote the quality and reliability of laboratory testing by providing nationally and internationally recognized accreditation services. Laboratories accredited by KOLAS are required to meet rigorous international standards set by the International Organization for Standardization (ISO) and are subject to regular assessments to ensure ongoing compliance with the standards. KOLAS accreditation is highly regarded both domestically and internationally, and is recognized for providing high-quality and reliable testing services. The nuclear analysis laboratory at KINAC has been working to establish a quality management system to ensure the external reliability of analytical results and to secure its position as an authorized testing agency. To achieve this, a detailed manual and procedure for nuclear material analysis were developed to conform to the international standards of ISO/IEC 17025. This study presents the preparation process for establishing the management system, focusing on meeting technical and quality requirements for the implementation of the ISO/IEC 17025 standard in the KINAC nuclear analysis laboratory, specifically in the field of chemical testing (dosimetry, radioactive, and neutron measurement subcategories). The preparation process involved two tracks. The first track focused on satisfying technical requirements, with Thermal Ionization Mass Spectrometer (TIMS) and Inductively Coupled Plasma-Mass Spectrometer (ICP-MS) selected as the major equipment for analysis. Analytical methods for determining isotope ratios and concentrations of nuclear materials were determined, and technical qualification was ensured through participation in proficiency test programs, inter-experimenter comparison tests, and uncertainty reports. The second track focused on developing the quality system, including quality manuals, procedures, and guidelines based on the requirements of the ISO/IEC 17025 standard. Various implementation documents were produced during the six-month pilot period, in accordance with the three levels of documents required by the standard. Implementation of ISO/IEC 17025 is expected to have a systematic quality management process for the analysis lab’s operations and to increase confidence in KINAC’s nuclear analysis.
        2.
        2019.06 KCI 등재 서비스 종료(열람 제한)
        관상동맥 조영술(CAG)의 씨네(Cine) 촬영에서 엑스선 촬영 조건의 변화가 입사 표면 선량(ESD)과 흡수 선량(DAP)에 미치는 관계를 알아보고자 하였고 image J 프로그램을 통해 촬영된 혈관 조영 영상의 SNR과 CNR을 측정·분석하여 조건 변화가 선량관계 및 영상의 질에 미치는 유용성을 분석하고자 하였다. 2017년 11월부터 2018년 3월까지 본원에서 CAG를 시행한 33명(남24, 여9)의 데이터를 대상으로 하였고, 연령대는 37-76세(평균 59±10세), 몸무게53-104kg (평균 72±10kg), 키150-185cm (평균 166.82±9.5kg), BMI 18.3-33.2(평 균 25.8±3.2)이었다. 촬영조건 및 데이터 획득은 관전류(mA)를 높게 한 A그룹(397.2mA)과 mA를 낮게 한 B 그룹(370.7mA)의 ESD와 DAP를 후향적으로 획득하여 비교․분석 하였고 Image J를 통한 SNR과 CNR 측정· 분석은 획득한 데이터를 공식에 대입하여 결과 값을 도출하였다. 통계프로그램은 SPSS (PASW)를 사용하여 촬영조건 변화에 따른 ESD와 DAP 및 SNR ․ CNR의 상관관계 등을 분석하였다. 촬영조건의 mA에 변화 를 주어 촬영한 A그룹과 B그룹의 ESD(A:483.5±60.1, B:464.4±39.9)와 DAP(A:84.3±10.7, B:81.5±7)간의 관계는 통계적으로 유의하지 않았다(p>0,05). Image J를 통한 SNR과 CNR의 관계에선 B그룹의 좌심장동맥(LC A)을 촬영해 얻은 영상의 SNR(5.451±0.529), CNR(0.411±0.0432)이 A그룹 좌심장동맥(LCA)의 SNR(4.976±0.4 33), CNR(0.459±0.0431)보다 SNR 0.475±0.096, CNR -0.048±0.0로 차이가 있었으나 통계적으로 유의하지는 않았다(p<0.05). 우심장동맥(RCA)을 촬영해 획득한 SNR과 CNR에선 A그룹의 SNR(4.731±0.773)과 CNR(0.3 54±0.083)이 B그룹의 SNR(3.24±0.368), CNR(0.166±0.033)보다 SNR 1.491±0.405, CNR 0.188±0.005로 증가된 수치를 나타냈으며 그 중 CNR이 통계적으로 유의했다(p<0.05). 상관관계 분석 결과에서는 SNR (LCA) & C NR (LCA), SNR (RCA) & CNR (RCA), ESD & DAP, ESD & sec, DAP & CNR (RCA), DAP & sec간에 통계적으로 유의한 차이를 나타냈다(p<0.05). SNR과 CNR이 높을수록 선명하고 좋은 화질을 나타냄을 의미하는 데 화질평가 및 선량변화 유용성에 관한 분석 연구를 진행한 결과 mA를 증가시켜 촬영 한 CAG의 RCA영 상에서 SNR과 CNR이 증가된 수치를 보였다. 특히, CNR이 통계적으로 유의한 차이를 나타낸 것을 보았을 때 RCA촬영 시 mA를 향상시켜 촬영 할 경우 영상의 질 중 대조도가 한층 더 향상 될 수 있을 것으로 사료 된다.