검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 5

        2.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Large amounts of oily wastewater discharged from various industrial operations (petroleum refining, machinery industries and chemical industries) cause serious pollution in the aquatic environment. Although dissolved air flotation (DAF) separating oil pollutants using microbubbles represents current practice, bubble size cannot be selectively controlled, and lots of power is required to generate microbubbles. Therefore, to investigate performance of the DAF process, this study examined the distribution of different sizes of microbubbles resulting from changes in physical shear force via modifying shapes of a slit-nozzle without an additional power supply. Three types of slit-nozzles (different angle, shape and length of the slit-nozzle) were used to analyze the distribution of bubble size. At a slit angle of 60°, shear force was 4.29 times higher than a conventional slit, and particle size distribution (PSD) in the range between 2 and 20 μm more than doubled. Treatment efficiency of synthetic oily wastewater through the coagulation-DAF process achieved 90% removal of COD by injecting FeCl3 and PACl of 250 mg/L and 100 mg/L, respectively, and the same performance resulted using FeCl3 of 200 mg/L and PACl of 80 mg/L employing a slit-nozzle angle of 60°. This study shows that a coagulation-DAF process using a modified slit-nozzle can improve the pre-treatment of oily wastewater.
        4,000원
        3.
        2017.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        분리막 오염을 감소시키고 투과유속 향상을 위하여 관형분리막 모듈 내에 공기 분사노즐관을 삽입시켰다. 분리막 의 평균 기공크기는 0.1 μm이며 이스트를 오염물질로 사용하였다. 모든 투과실험은 노즐관을 모듈에 장착하고 공기를 주입 하지 않는 실험을 먼저 실시하고 연속해서 공기를 주입하는 투과실험을 하였다. 그 다음 노즐관을 제거한 후 공기를 주입시 키지 않으면서 투과유속을 측정하였다. 측정된 투과유속은 공기주입 효과를 분석하기 위하여 비교하였다. 공기주입에 대한 투과유속은 거의 일정하거나 증가하였다. 노즐관이 장착되고 공기 주입을 하지 않을 경우의 투과유속이 빈 관형 모듈의 경우 보다 높았다. 운전압력을 0.4 bar까지 감소시키면 노즐관이 장착되지 않는 경우와 비교하여 공기를 주입할 경우 투과유속이 21%까지 향상되었다. 기체량이 증가하여 기/액체 2상 흐름이 stratified-smooth에서 intermittent 상태로 변화됨에 따라서 공기 주입에 의한 투과유속은 30% 이상으로 증가하였다
        4,000원
        4.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In recent years, there was many conflagration about special structure such as wooden cultural assets, warehouses and factories. The common causes of increase in the fire damage were difficulty of the initial suppression and absence of equipment for appropriate disaster prevention. A prediction of the air injection diameter of the destruction-spray nozzle, a core technology of destruction-spray fire vehicle which is possible for fire suppression of special structure were studied. As a result, changes in water flow according to the air injection diameter is not large, but air flow rate showed a difference more than up to four times. And then, through the result data of the flow analysis, the air injection diameter was obtained in the target mix ratio of the air according to the water injection pressure. Finally, by the formula derivation for the air injection diameter of target mix ratio of the air, the air injection diameter according to the water injection pressure change could be predicted within an error of 10%.
        4,000원
        5.
        2012.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        여름철 고온기 온실 내 효율적 증발냉방을 위하여 다량 포그 분무가 가능하고 설치비용이 저렴하도록 한 터보팬 2류체 노즐로 포그 분무장치를 구성하고 소형 유리온실에 2.2 m 높이로 설치하여 냉방시험을 실시하였다. 이 장치의 분무시험 결과 평균분무입경이 29 ㎛이고 1대당 포그 분무량은 160 ㎖/min로 비산반경 2 m이내에서 입자들이 모두 증발하는 것으로 나타났다. 이 장치를 평면적 228 ㎡인 단동 유리온실에 2대를 설치하여 냉방실험한 결과, 외기의 온도 30.2℃, 상대습도 81.2%인 때 온실 내 공기의 온도 28.8℃, 상대습도 87.5%의 낮은 냉각효과를 나타내었다. 문헌 조사와 냉방실험 결과로부터 여름철 우리나라 남부지역의 외기온 35℃를 기준으로 단동온실은 50% 차광에서 증발냉각에 의해 온실 내 공기온도를 외기온보다 2∼3℃ 낮추려면 환기회수 1회/분, 물분무량은 10 ㎖/min/㎡인 것으로 추정되었다.
        4,000원