For the OPR1000, a standard power plant in Korea, an analytical model of the containment building considering voids and deterioration was built with multilayer shell elements. Voids were placed in the vulnerable parts of the analysis model, and the deterioration effects of concrete and rebar were reflected in the material model. To check the impact of voids and deterioration on the seismic performance of the containment building, iterative push-over analysis was performed on four cases of the analytical model with and without voids and deterioration. It was found that the effect of voids with a volume ratio of 0.6% on the seismic performance of the containment building was insignificant. The effect of strength reduction and cross-sectional area loss of reinforcement due to deterioration and the impact of strength increase of concrete due to long-term hardening offset each other, resulting in a slight increase in the lateral resistance of the containment building. To determine the limit state that adequately represents the seismic performance of the containment building considering voids and deterioration, the Ogaki shear strength equation, ASCE 43-05 low shear wall allowable lateral displacement ratio, and JEAC 4601 shear strain limit were compared and examined with the analytically derived failure point (ultimate point) in this study.
국내 수출입 물동량의 증가와 해운산업의 발달에 따라 항만시설물의 사용빈도 또한 증가 추세에 있으나, SOC의 해운항만 부문의 투입 정부예산은 감축되어 왔다. 증가하는 사용빈도에 반하여 줄고 있는 예산으로 인해 항만시설물의 체계적이고 효율적인 유지관리 및 운영이 필요하다. 효율적인 유지관리 시스템 구축을 위해서 항만시설물이 위치한 지역, 구조물의 형태 및 취급화종, 시공 및 유지관리 수준과 같은 특성을 고려한 열화모델 개발이 필요하다. 항만시설물의 열화모델 개발은 시설물의 열화요인 분석과 열화데이터 수집 및 열화 모델 개발의 과정으로 수행하였다. 열화 모델 개발기법은 변수 특성에 따른 시간 의존적 상태변화를 반영할 수 있는 결정론적 방법인 다중 회귀분석과 변동성이 큰 자료들의 상태이력을 반영할 수 있는 확률론적 방법인 마코브 체인 이론을 이용하였다. 각 방법을 통해 잔교식 구조물과 블록식 구조물의 Project level의 상태 열화모델을 제시하였다.