In this paper, a heat exchange system using cooling dehumidification and mixing process was proposed as an experimental study for a white smoke reduction heat exchanger system under winter condition. The white smoke reduction heat exchange system is divided into an EA part, SA part, W part and mixing zone. For the operating conditions, three types (Cases 1, 2, and 3) were selected depending on whether EA fan, SA fan, and A-W heat exchanger were operated. In addition, in order to visualize the white smoke exhausted from the mixing zone, it was photographed using CCTV. In order to investigate the performance of the white smoke reduction heat exchange system, the temperature reduction rate and absolute humidity reduction rate of EA and the heat recovery rate of W were calculated. The temperature change of EA and SA according to operating conditions was most effective in Case 3, and the temperature and absolute humidity at the outlet of the mixing zone were greatly reduced. From the results of the white smoke visualization, it was confirmed that the white smoke generation mechanism was different depending on the operating conditions, and the amount of white smoke generation was greatly reduced.
절대 습도와 이슬점 온도의 관계에 대한 예비 교사들의 인식을 조사하기 위하여 설문지를 투입하였다. 설문 결과 예비 교사들이 “절대 습도와 이슬점 온도는 비례한다.”, “이슬점 온도는 공기 중의 수증기의 질량에 비례한다.”와 같은 견고한 오개념을 갖고 있음을 발견하였다. 예비 교사들이 갖는 이러한 오개념은 절대 습도와 이슬점 온도의 관계에 대한 7차 교육과정과 2007 개정 교육과정 중학교 과학 교과서의 부정확한 서술 내용에서 기인하는 것으로 사료된다. 한편, 2015 개정 교육과정 중학교 1학년 과학 교과서는 증발, 응결, 압력과 온도 변화에 따른 기체의 부피 변화를 분자 운동의 관점에서 다루기 때문에, 중학교 교육과정에서 이러한 관점을 유지하기 위해 수증기량과 이슬점 온도의 척도로서 수증기압의 도입은 예비 교사와 학습자의 오개념을 방지할 수 있으며, 과학 교육과정을 보다 일관되고 논리적으로 만들 수 있을 것으로 사료된다.