When adjacent tall buildings experience earthquake excitation, structural pounding may happen. In order to mitigate seismic pounding damage to adjacent structures, many studies have been done to date. Tuned mass dampers (TMD) are widely used for reduction of dynamic responses of building structures subjected to earthquake excitations. If a TMD is shared between adjacent buildings and it shows good control performance, it will be effective and economic means to reduce seismic responses of adjacent structures. In this study, control performance of a shared tuned mass damper (STMD) for seismic response reduction of adjacent buildings has been evaluated. For this purpose, two 8-story example buildings were used and multi-objective genetic algorithms has been employed for optimal design of the stiffness and damping parameters of the STMD. Based on numerical analyses, it has been shown that a STMD can effectively control dynamic responses and reduce the effect of pounding between adjacent buildings subjected to earthquake excitations in comparison with a traditional TMD.
In recently, sky-bridge are often applied to high-rised adjacent buildings for pedestrian bridge. the seisnic response control of adjacent buildings have been studied and magneto-rheological(MR) fluid dampers have been applied to seismic response control. In this study, vibration control effect of the MR damper connected adjacent buildings has been investigated. Adjacent building structures with different natural frequencies were used as example structures. Two typed of control methods, displacement based or velocity based, are applied to determinate control force of MR damper. In this numerical analysis, it has been shown that displacement-based control algorithm is more effective than velocity-based control algorithm for seismic response control of adjacent buildings. And, when displacement-based control method is applied to control of adjacent buildings, the control of building occurred large displacement is more efficient in reducing the seismic response.
현재 건축 및 토목 구조물의 진동제어에 있어서 준능동제어에 대한 연구가 많이 수행되고 있으며 준능동제어 시스템은 수동제어와 능동제어의 장점을 가지고 있다. 최근 적은 전기 에너지로 제어가 가능한 MR 감쇠기가 개발되어 준능동제어 분야에 적용되고 있으며 이러한 MR 감쇠기를 스마트 감쇠기라 불리고 있다. 본 논문에서는 실시간으로 제어가 가능한 MR 감쇠기를 인접한 두 건축물 사이에 설치하여 제어성능을 알아보고자 한다. 또한, groundhook과 skyhook 제어 알고리즘을 결합한 복합제어 모델을 인접한 건축물의 진동제어에 적용하여 복합제어 모델의 제어성능을 알아보고자 한다. 복합제어 모델을 적용하여 인접한 두 건축물의 진동제어 성능을 분석한 결과, 복합제어 모델이 인접한 두 건축물의 진동제어에 매우 효과적인 것을 알 수 있었다.
본 연구에서는 MR 감쇠기와 FPS를 사용하여 구성된 스마트 스카이브릿지를 제안하였으며 스마트 스카이브릿지로 연결된 인접건물의 지진응답 제어성능을 분석하였다. 이를 위하여 스마트 스카이브릿지로 연결된 10층과 20층 구조물을 예제 구조물로 선택하였고 근거리 (near fault) 및 원거리 (far fault) 지진의 특성을 가지는 El Centro 지진과 Kobe지진을 사용하여 시간이력해석을 수행하였다. 스마트 스카이브릿지블 효과적으로 제어하기 위해서 퍼지논리제어기를 개발하였으며 퍼지논리제어기를 최적화하기 위하여 다목적 유전자알고리즘을 사용하였다. 최적화결과 10층 건물의 지진응답과 20층 건물의 지진응답 사이에는 상충관계 (trade-off)가 있는 것을 알 수 있었고 다목적 유전자알고리즘을 통해서 두 건물의 지진응답 제어에 대한 퍼지논리제어거의 파레토 해집합을 구할 수 있었다. 수치해석결과 본 연구에서 제안한 스마트 스카이브릿지를 사용하면 연결된 건물의 지진응답을 효율적으로 저감시킬 수 있는 것을 알 수 있었다.