검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 2

        1.
        2007.08 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 안양천 유역에 대해 HSPF 모형을 구축하고 중유역과 전체유역의 물순환 현황 및 BOD 부하량을 정량적으로 파악하였다. 모형을 구축하기 위해 HSPF모형의 수량 및 BOD 농도에 대한 민감도 분석을 수행하여 매개변수를 선택하였다. 또한 다양한 특성을 갖고 있는 안양천 유역을 토지이용, 경사도 및 사용한 기상자료 등에 따라 4개 지역으로 구분하여 검 보정을 실시하여 정확도를 향상시켰다. 물순환 모의 결과 하류로 갈수록 도시화 비율이 높으며
        2.
        2001.02 KCI 등재 서비스 종료(열람 제한)
        The Keum river has been utilized for drinking water supply of several city including Kunsan city and is deepening pollution state due to numerous municipal and industrial discharges. The concentration BOD in river is affected by the organic loading from a tributary and the algae biomass that largely happen to under eutrophication state. In the eutrophic water mass such as the Keum river, the autochthonous BOD was very important part for making a decision of water quality management, because it was accounted for majority of the total BOD. The predict of water quality has important meaning for management of water quality pollution of the Keum river. The purpose of this study will manage and predict water quality of the Keum river using QUAL-2E model considering the autochthonous BOD. The estimation of autochthonous BOD represented that the relationship between BOD and chlorophyll a. The regression equation was shown to be autochthonous BOD=β5×chlorophyll a. The results of this study may be summarized as followed; The QUAL-2E model was calibrated with the data surveyed in the field of the study area in June, 1998. The calculated value by QUAL-2E model are in good agree to measured value within relative error of 7.80∼20.33%. Especially, in the case of the considering autochthonous BOD, the calculated value of BOD were fairly good coincided with the observed values within relative error of 15%. But the case of not considering autochthonous BOD, relative error of BOD was shown to be 43.2%. In order to attain Ⅱ grade of water quality standard in Puyo station which has a intake facility of water supply, we reduced to the pollutants loading of tributaries. In the case of removed 100% BOD of tributaries, the BOD of Puyo station was 4.07㎎/ℓ, belong to Ⅲ grade of water quality standard. But in the case of removed 88% nutrient of tributaries, it was satisfied to Ⅱ grade of water quality standard as below 3㎎/ℓof BOD. For estimation of autochthonous BOD in Keum river, we are performed simulating in accordance with reduction of nutrient load(50∼100%) under conditions removal 90% organic load. Occupancy of autochthonous BOD according to nutrient loading reductions were varied from 25.97∼79.51%. Occupancy of autochthonous BOD was shown to be a tendency to increasing in accordance with reduction of nutrient loading. Showing the above results, the nutrient that one of the growing factor of algae was important role in decision of BOD in the Keum river. For the water quality management of the Keum river, therefore, it is necessary to considering autochthonous BOD and to construction of advanced sewage treatment plant for nutrient removal.