This study is done as a comparison analysis on existing studies on analysis and interpretations of solenoids. When there is no power in a solenoid valve, a flow passage is formed from a pressurized ports, Pc, to Ps, which are connected to a crankcase of a pressurizer. An inlet to Pc port is varied in three different sizes: 3.8 ㎜(Type-1), 4.0 ㎜(Type-2) and 4.2 ㎜(Type-3). It is determined that there will be changes in coolant flow into the solenoid valve and the flow properties from Pc port to Ps port are compared and analyzed. As the results, the flow demonstrates the maximum speed of 500 ㎧, 46 ㎧ and 433 ㎧ with 0.2 ㎫ for the inflow pressure and the maximum speed of 1400 ㎧, 129 ㎧ and 1200 ㎧ with 1.5 ㎫ for the inflow pressure.
This paper carried out a comparative analysis with papers on the analysis and analytic research of conventional solenoid. In case the current of solenoid valve is cut off, a flow path is formed from pressure port (Pc) connected with the crankcase of compressor to Ps port. At this time, the size of Pc port hole was so adjusted (Type-2) that it was smaller than 4.0mm(Type-1) of original hole by 0.2mm. After that, it was thought that an effect would be produced on the flow change of refrigerant which came into the solenoid vale, therefore the flow characteristics in moving from Pc port to Ps port was predicted and comparatively analyzed. According to the results of flow analysis, a velocity of approximately 46m/s and 129m/s was shown at the maximum in case of 0.2 and 1.5 MPa in Type-1, and the maximum velocity of approximately 500m/s and 1400m/s was shown in case of Type-2.